Related Experiment Video
Updated: Aug 8, 2025

Clean Sampling and Analysis of River and Estuarine Waters for Trace Metal Studies
Published on: July 1, 2016
Improvement of Advanced Sample Preparation Systems for the Determination of Trace Ni in Seawater by Electro-Membranes
Juan J Pinto1, Carolina Mendiguchía1, José A López-López1
1Department of Analytical Chemistry, Faculty of Marine and Environmental Sciences, University of Cadiz, 11510 Puerto Real, Spain.
Abstract:
Due to its important environmental role, the analysis of trace metals in natural waters is attracting increasing attention; consequently, faster and more accurate analytical methods are now needed to reach even lower limits of detection. In this work, we propose the use of electro-membrane extraction (EME) to improve analytical methods based on hollow fiber liquid phase micro-extraction (HFLPME). Specifically, an EME-based method for the determination of trace Ni in seawater has been developed, using an HFLPME system with di-2-ethylhexyl phosphoric acid (DEHPA) in kerosene as a chemical carrier, followed by instrumental determination by graphite furnace atomic absorption spectroscopy (GFAAS). Under optimum conditions, Ni was pre-concentrated 180 ± 17 times after 15 min, using sample pH = 5.5, the concentration of DEHPA 0.9 M in the liquid membranes, and 1.9 M HNO3 in the acceptor solution, as well as an electric potential of 25 V with the sample being stirred at 500 rpm. When compared with other HFLPME systems for pre-concentration of trace Ni in seawater in the absence of electric potential, the enrichment factor was improved 2.2 times, while the time of extraction was reduced an 89%. The limit of detection of the new method was 23.3 ng L-1, and both its applicability and accuracy were successfully evaluated by analyzing Ni concentration in a seawater-certified reference material (BCR-403), showing the reliability of EME for sample preparation in the determination of trace metals in marine water samples.
More Related Videos
08:57VacuSIP, an Improved InEx Method for In Situ Measurement of Particulate and Dissolved Compounds Processed by Active Suspension Feeders
Published on: August 3, 2016
09:42Fabrication of a Dipole-assisted Solid Phase Extraction Microchip for Trace Metal Analysis in Water Samples
Published on: August 7, 2016
Related Concept Videos
Precipitation Gravimetry
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...
Electrodeposition
Electrodeposition can...
Preparation of Samples for Electron Microscopy
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...