Just-in-time adaptive ecological momentary assessment (JITA-EMA)
Stefan Schneider1,2,3, Doerte U Junghaenel4,5,6, Joshua M Smyth7
1Dornsife Center for Self-Report Science & Center for Economic and Social Research, University of Southern California, 635 Downey Way, Los Angeles, CA, 90089-3332, USA. schneids@usc.edu.
Abstract:
Interest in just-in-time adaptive interventions (JITAI) has rapidly increased in recent years. One core challenge for JITAI is the efficient and precise measurement of tailoring variables that are used to inform the timing of momentary intervention delivery. Ecological momentary assessment (EMA) is often used for this purpose, even though EMA in its traditional form was not designed specifically to facilitate momentary interventions. In this article, we introduce just-in-time adaptive EMA (JITA-EMA) as a strategy to reduce participant response burden and decrease measurement error when EMA is used as a tailoring variable in JITAI. JITA-EMA builds on computerized adaptive testing methods developed for purposes of classification (computerized classification testing, CCT), and applies them to the classification of momentary states within individuals. The goal of JITA-EMA is to administer a small and informative selection of EMA questions needed to accurately classify an individual's current state at each measurement occasion. After illustrating the basic components of JITA-EMA (adaptively choosing the initial and subsequent items to administer, adaptively stopping item administration, accommodating dynamically tailored classification cutoffs), we present two simulation studies that explored the performance of JITA-EMA, using the example of momentary fatigue states. Compared with conventional EMA item selection methods that administered a fixed set of questions at each moment, JITA-EMA yielded more accurate momentary classification with fewer questions administered. Our results suggest that JITA-EMA has the potential to enhance some approaches to mobile health interventions by facilitating efficient and precise identification of momentary states that may inform intervention tailoring.
More Related Videos
Related Concept Videos
Pulse Assessment Sites
Nursing Assessment
The nurse collects all aspects of the patient's health in the initial assessment, establishing priorities for ongoing focused assessments...
Ecological Disturbance
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
The Availability Heuristic
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement: