Related Experiment Video
Updated: Aug 8, 2025

Computerized Dynamic Posturography for Postural Control Assessment in Patients with Intermittent Claudication
Published on: December 11, 2013
Maximal calf conductance is associated with 6-minute walk distance in participants with and without peripheral artery
Andrew W Gardner1,2, Polly S Montgomery1,2, Ming Wang3
1Department of Physical Medicine & Rehabilitation, Penn State College of Medicine, Hershey, PA, USA.
Introduction:
The aims were (a) to compare the maximal calf conductance and 6-minute walk distance of participants with and without peripheral artery disease (PAD) and claudication, (b) to determine whether maximal calf conductance was more strongly associated with 6-minute walk distance in participants with PAD than in the controls, and (c) to determine whether this association was significant in participants with PAD after adjusting for ABI, as well as for demographic, anthropometric, and comorbid variables.
Methods:
Participants with PAD (n = 633) and without PAD (n = 327) were assessed on maximal calf conductance using venous occlusion plethysmography, and on 6-minute walk distance. Participants were further characterized on ABI, and on demographic, anthropometric, and comorbid variables.
Results:
The PAD group had lower maximal calf conductance than the control group (0.136 ± 0.071 vs 0.201 ± 0.113 mL/100 mL/min/mmHg, p < 0.001). Additionally, the PAD group had a lower 6-minute walk distance (375 ± 98 m vs 480 ± 107 m, p < 0.001). Maximal calf conductance was positively associated with 6-minute walk distance in both groups (p < 0.001) and was more strongly associated in the PAD group (p < 0.001). In adjusted analyses, maximal calf conductance remained positively associated with 6-minute walk distance in the PAD group (p < 0.001) and in the control group (p < 0.001).
Conclusions:
Participants with PAD and claudication had impaired maximal calf conductance and a lower 6-minute walk distance than those without PAD, and maximal calf conductance was positively and independently associated with 6-minute walk distance within each group before and after adjusting for ABI, and for demographic, anthropometric, and comorbid variables.
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Peripheral Artery Disease I: Introduction
Peripheral Artery Disease IV: Nursing Management
Peripheral Artery Disease III: Interprofessional Care
Peripheral Artery Disease V: Postoperative Nursing Management
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...

