Related Experiment Video
Updated: Aug 8, 2025

Biosensor-based High Throughput Biopanning and Bioinformatics Analysis Strategy for the Global Validation of Drug-protein Interactions
Published on: December 1, 2020
Data mining and analysis for emicizumab adverse event signals based on the Food and Drug Administration Adverse Event
Lianhui Wei1, Ye Tian2, Xiao Chen1
1Department of Health Statistics, Faculty of Health Service, Naval Medical University, Shanghai, 200433, China.
Background:
Emicizumab is the latest treatment for patients with hemophilia A. Its safety in real-world data is limited, and regulatory agencies and clinical researchers have raised concerns about the risk of adverse events.
Aim:
This study aimed to detect potential adverse event signals of emicizumab using the FDA Adverse Event Reporting System (FAERS) database.
Method:
Data in FAERS from the fourth quarter of 2017 to the second quarter of 2021 were searched. Cases of adverse events were extracted using the Preferred Term in the Medical Dictionary for Regulatory Activities (version 24.0). Disproportionality analysis was performed using the reporting odds ratio (ROR) and information component (IC) methods based on statistical shrinkage transformation.
Results:
A total of 5,598,717 patients were included, of which 1,244 took emicizumab. A total of 703 emicizumab-related adverse event signals were mined, and 101 positive signals were detected. Haemarthrosis (ROR/ROR975/ROR025 = 155.62/184.34/131.38, IC/IC975/IC025 = 7.28/7.48/7.01), haemorrhage (ROR/ROR975/ROR025 = 71.01/81.18/62.12, IC/IC975/IC025 = 6.15/6.31/5.94), muscle haemorrhage (ROR/ROR975/ROR025 = 53.38/75.83/37.58, IC/IC975/IC025 = 5.74/6.16/5.15), traumatic haemorrhage (ROR/ROR975/ROR025 = 27.78/46.29/16.67, IC/IC975/IC025 = 4.80/5.40/3.92), haematoma (ROR/ROR975/ROR025 = 18.15/26.35/12.51, IC/IC975/IC025 = 4.18/4.63/3.55), device-related thrombosis (ROR/ROR975/ROR025 = 21.27/37.57/12.04, IC/IC975/IC025 = 4.41/5.08/3.43), and activated partial thromboplastin time prolonged (ROR/ROR975/ROR025 = 20.68/36.51/11.71, IC/IC975/IC025 = 4.37/5.04/3.39) had the strongest signal intensities. Haemorrhage, haemarthrosis, arthralgia, fall, and injection site pain were reported more frequently.
Conclusion:
This study found that mild arthralgia and injection site reaction were associated with emicizumab. Attention should also be paid to other serious adverse events related to emicizumab, such as acute myocardial infarction and sepsis, to ensure patient safety.
More Related Videos
Related Concept Videos
Pharmacovigilance
This process, termed pharmacovigilance, aims to detect, evaluate, and minimize harmful effects related to medication use. The data collection for pharmacovigilance depends on spontaneous reporting systems, where healthcare professionals or patients voluntarily report suspected ADRs.
In some cases, there...
Drug Regulation