Vibration and current dataset of three-phase permanent magnet synchronous motors with stator faults
Wonho Jung1, Sung-Hyun Yun1, Yoon-Seop Lim1
1Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, 291, Daehak-ro, Yuseong-gu, Daejeon, 34141, South Korea.
Abstract:
Permanent magnet synchronous motors (PMSM) are widely used in industry applications such as home appliances, manufacturing process, high-speed trains, and electric vehicles. Unexpected faults of PMSM are directly related to the significant losses in the engineered systems. The majority of motor faults are bearing fault (mechanical) and stator fault (electrical). This article reports vibration and driving current dataset of three-phase PMSM with three different motor powers under eight different severities of stator fault. PMSM conditions including normal, inter-coil short circuit fault, and inter-turn short circuit fault in three motors are demonstrated with different powers of 1.0 kW, 1.5 kW and 3.0 kW, respectively. The PMSMs are operated under the same torque load condition and rotating speed. Dataset is acquired using one integrated electronics piezo-electric (IEPE) based accelerometer and three current transformers (CT) with National Instruments (NI) data acquisition (DAQ) board under international organization for standardization standard (ISO 10816-1:1995). Established dataset can be used to verify newly developed state-of-the-art methods for PMSM stator fault diagnosis. Mendeley Data. DOI: 10.17632/rgn5brrgrn.5.
Related Concept Videos
Three-Phase Short Circuit—Unloaded Synchronous Machine
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
Power System Three-Phase Short Circuits
Electro-mechanical Systems
A key component of the DC motor is the armature, a rotating circuit positioned within a magnetic field. As an electric current passes through the...
Torque On A Current Loop In A Magnetic Field
Consider a rectangular current-carrying loop containing N turns of wire, placed in a uniform magnetic field. The net force on a current-carrying loop...
Generation of Three-Phase Voltage
As the rotor...
Bus Impedance Matrix
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...