Omentin-1 Levels and Outcomes in Incident Peritoneal Dialysis Patients

Win Hlaing Than1,2, Gordon Chun-Kau Chan1, Bonnie Ching-Ha Kwan1

  • 1Carol & Richard Yu Peritoneal Dialysis Research Centre, Department of Medicine & Therapeutics, Prince of Wales Hospital, Faculty of Medicine, The Chinese University of Hong Kong, Shatin, Hong Kong, China.

Kidney Medicine
|February 28, 2023
PubMed
Abstract

Related Concept Videos

Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications01:25

Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications

Peritoneal dialysis (PD) is a medical process that removes waste products and excess fluid from the body using the peritoneal membrane as a natural filter.Peritoneal Dialysis MethodsSeveral methods can be used for peritoneal dialysis, including Acute Intermittent Peritoneal Dialysis, Continuous Ambulatory Peritoneal Dialysis, and Automated Peritoneal Dialysis, also known as Continuous Cyclic Peritoneal Dialysis.Acute Intermittent Peritoneal Dialysis (AIPD) is used for patients with uremic...
55
Peritoneal Dialysis III: Nursing Management01:25

Peritoneal Dialysis III: Nursing Management

Peritoneal dialysis, or PD, utilizes the peritoneal membrane as a filter to eliminate excess fluid and waste products. Effective nursing management is essential for ensuring patient safety, preventing complications, and promoting optimal function of the peritoneal dialysis process.Assessment and MonitoringNurses must thoroughly assess the patient before, during, and after each dialysis session. Regular monitoring includes vital signs, daily weight, fluid intake and output, and laboratory values...
68
Peritoneal Dialysis I: Introduction and Procedure01:30

Peritoneal Dialysis I: Introduction and Procedure

Peritoneal dialysis (PD) is a procedure that facilitates the exchange of solutes, waste products, electrolytes, and excess fluid between the blood in the peritoneal capillaries and a dialysis solution introduced into the peritoneal cavity.Principles of Peritoneal Dialysis (PD)Diffusion: Waste products such as urea and electrolytes move from high concentrations in the blood to low concentrations in the dialysate across the peritoneal membrane. This mechanism is driven by the concentration...
85
Hemodialysis III: Nursing Management01:25

Hemodialysis III: Nursing Management

The nursing management of a patient undergoing hemodialysis includes several critical steps, starting with a thorough assessment before the procedure.Before the Hemodialysis ProcedureFirst, record the patient's vital signs—blood pressure, heart rate, respiratory rate, and temperature—to establish a baseline. This baseline is essential for detecting conditions such as hypotension that could impact the patient's response to dialysis. Document the patient's pre-dialysis weight, as this...
67
Hemodialysis II: Procedure and Complications01:24

Hemodialysis II: Procedure and Complications

DialyzersA hemodialysis (HD) dialyzer is a plastic cartridge containing thousands of parallel hollow fibers, which serve as semipermeable membranes. These fibers are typically made from cellulose-based or other synthetic materials. During HD, blood is pumped into the top of the cartridge and distributed among these fibers. Simultaneously, dialysis fluid, known as dialysate, is introduced into the bottom of the cartridge, bathing the outside of the fibers. Across the semipermeable membrane,...
46
Renal Failure: Dose Adjustments01:11

Renal Failure: Dose Adjustments

In patients with renal impairment, drugs undergo significant changes in their pharmacokinetics, which require dosage adjustments to ensure safe and effective therapy.
Reduced renal clearance and elimination rate are common outcomes of renal impairment. These alterations lead to a prolonged elimination half-life and an altered apparent volume of distribution for drugs. As a result, dosage adjustments are typically necessary to maintain optimal drug levels in the body.
However, dosage adjustments...
128