Related Experiment Video
Updated: Aug 8, 2025

Magnetic Resonance Imaging of Multiple Sclerosis at 7.0 Tesla
Published on: February 19, 2021
Mobile Technology in Medicine: Development and Validation of an Adapted System Usability Scale (SUS) Questionnaire
Wai-Hun Cheah1, Norhasiza Mat Jusoh1, Myat Moe Thwe Aung1
1Faculty of Medicine Universiti Sultan Zainal Abidin, Kuala Terengganu, Terengganu, Malaysia.
Abstract:
Background Magnetic resonance imaging (MRI) safety screening is a crucial procedure for patient preparation before entering into MRI room. Many hospitals in Malaysia are still using the MRI safety checklist printed form. Besides, clinicians will not get a definite conclusion about whether the patient is contraindicated for MRI or not. Hence, we have created one mobile application named MagnetoSafe to overcome this issue. The application will provide an instant decision on whether the patient has no contraindication, relative contraindication, or absolute contraindicated for MRI. We need to check for acceptability and user experience for any newly created mobile application. Objective This study was designed to check the validity of the adapted Technology Acceptance Model (TAM) and System Usability Scale (SUS) Questionnaire. Method The validity and reliability of the questionnaire were investigated. Subsequently, 52 fully completed responses were collected. Results Face and content validity of the questionnaires are considered acceptable with only minor changes to Item 10 of SUS. The Cronbach's alpha for the SUS questionnaire (10 questions) is -0.49, which is not acceptable. The Cronbach's alpha for TAM questionnaire (3 domains; 14 questions) is acceptable, which is 0.910 for perceived usefulness, 0.843 for perceived ease of use, and 0.915 for intention to use. Conclusion Face validity of the adapted SUS and modified TAM questionnaires is acceptable with only minor changes to Item 10 in SUS. Content validity with experts is good. However, the reliability of the SUS questionnaire is not acceptable and therefore adapted SUS will not be used for assessing user experience. The reliability of the modified TAM questionnaire with the original three-factor structure is considered acceptable and can be used to evaluate the user's acceptability of MagnetoSafe.
More Related Videos
15:18Making MR Imaging Child's Play - Pediatric Neuroimaging Protocol, Guidelines and Procedure
Published on: July 30, 2009
08:19Protocol for the Evaluation of MRI Artifacts Caused by Metal Implants to Assess the Suitability of Implants and the Vulnerability of Pulse Sequences
Published on: May 17, 2018
Related Concept Videos
Imaging Studies IV: Magnetic Resonance Imaging
Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System IV: CMRI