Related Experiment Video
Updated: Aug 8, 2025

Characterization of Sickling During Controlled Automated Deoxygenation with Oxygen Gradient Ektacytometry
Published on: November 5, 2019
Hemoglobin Denver, a cause of desaturated pulse oximetry. A pediatric case report
Estefanía Rossetti1, Silvia Eandi Eberle2, Fernando Aguirre2
1Department of Hematology and Oncology; Hospital de Pediatría S.A.M.I.C. Prof. Dr. Juan P. Garrahan, City of Buenos Aires, Argentina.
Hemoglobinopathies are genetic disorders that affect the hemoglobin (Hb) molecule. Mutations in the alpha or beta chains altering the Hb tetramer may modify the molecule's oxygen-binding capacity. Hemoglobinopathies with low oxygen affinity may occur with cyanosis and an altered pulse oximetry reading, leading to unnecessary and sometimes invasive tests to rule out cardiovascular and respiratory conditions. In the case report described here, we present an asymptomatic pediatric patient who consulted for desaturated pulse oximetry. Her initial laboratory tests showed normocytic, normochromic anemia. Venous blood gas samples showed an elevated p50. After using extensive diagnostic tools, a variant of Hb with low oxygen affinity was diagnosed: Hb Denver.
Hemoglobinopathies are genetic disorders that affect the hemoglobin (Hb) molecule. Mutations in the alpha or beta chains altering the Hb tetramer may modify the molecule's oxygen-binding capacity. Hemoglobinopathies with low oxygen affinity may occur with cyanosis and an altered pulse oximetry reading, leading to unnecessary and sometimes invasive tests to rule out cardiovascular and respiratory conditions. In the case report described here, we present an asymptomatic pediatric patient who consulted for desaturated pulse oximetry. Her initial laboratory tests showed normocytic, normochromic anemia. Venous blood gas samples showed an elevated p50. After using extensive diagnostic tools, a variant of Hb with low oxygen affinity was diagnosed: Hb Denver.
More Related Videos
04:10Author Spotlight: Exploring Venous Waveforms for Non-Invasive Respiratory Monitoring in Pigs
Published on: March 8, 2024
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Hypoxia
Types of Hypoxia
There are four primary types of hypoxia, each resulting from a different cause:
1. Anemic hypoxia: This type occurs due to insufficient oxygen delivery caused by a lack of red blood cells (RBCs) or RBCs with abnormal or...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Oxygen Transport in the Blood
Hemoglobin
When all four heme groups are bound to oxygen, the resulting molecule is called oxyhemoglobin. As a result, arterial blood...