Near single-photon imaging in the shortwave infrared using homodyne detection
O Wolley1, S Mekhail1, P-A Moreau2,3
1School of Physics and Astronomy, University of Glasgow, Glasgow G12 8QQ, UK.
Abstract:
Low-light imaging is challenging in regimes where low-noise detectors are not yet available. One such regime is the shortwave infrared where even the best multipixel detector arrays typically have a noise floor in excess of 100 photons per pixel per frame. We present a homodyne imaging system capable of recovering both intensity and phase images of an object from a single frame despite an illumination intensity of ≈1 photon per pixel. We interfere this weak signal which is below the noise floor of the detector with a reference beam that is ∼300, 000 times brighter, record the resulting interference pattern in the spatial domain on a detector array, and use Fourier techniques to extract the intensity and phase images. We believe our approach could vastly extend the range of applications for low-light imaging by accessing domains where low-noise cameras are not currently available and for which low-intensity illumination is required.