Clinical performance comparison of two medium cut-off dialyzers

Detlef H Krieter1, Marieke Rüth2, Horst-Dieter Lemke2

  • 1Division of Nephrology, University Hospital Würzburg, Würzburg, Germany.

Summary

The Nipro ELISIO-17HX MCO dialyzer offers comparable middle molecule removal to Baxter Theranova but with significantly lower albumin loss. This new option expands choices for medium-cut-off hemodialysis patients.

Related Concept Videos

Dialysis01:15

Dialysis

Dialysis is a diffusion-based purification process that separates analyte molecules from a complex matrix. This is accomplished by allowing molecules in the solution to pass through a semipermeable membrane into a liquid on the other side. The membrane is usually made of cellulose acetate or cellulose nitrate, and the second liquid must be miscible with the solution. Ions (e.g., chloride or sodium) or organic molecules (e.g., glucose) can pass through the membrane pores, which generally have...
754
Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications01:25

Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications

Peritoneal dialysis (PD) is a medical process that removes waste products and excess fluid from the body using the peritoneal membrane as a natural filter.Peritoneal Dialysis MethodsSeveral methods can be used for peritoneal dialysis, including Acute Intermittent Peritoneal Dialysis, Continuous Ambulatory Peritoneal Dialysis, and Automated Peritoneal Dialysis, also known as Continuous Cyclic Peritoneal Dialysis.Acute Intermittent Peritoneal Dialysis (AIPD) is used for patients with uremic...
55
Hemodialysis II: Procedure and Complications01:24

Hemodialysis II: Procedure and Complications

DialyzersA hemodialysis (HD) dialyzer is a plastic cartridge containing thousands of parallel hollow fibers, which serve as semipermeable membranes. These fibers are typically made from cellulose-based or other synthetic materials. During HD, blood is pumped into the top of the cartridge and distributed among these fibers. Simultaneously, dialysis fluid, known as dialysate, is introduced into the bottom of the cartridge, bathing the outside of the fibers. Across the semipermeable membrane,...
46
Hemodialysis I: Introduction01:25

Hemodialysis I: Introduction

Hemodialysis (HD) is a medical treatment that artificially removes waste products, excess fluids, and toxins from the blood when the kidneys are no longer able to perform these functions effectively. In this process, blood is filtered through a semipermeable membrane, allowing for the selective removal of waste while preserving necessary components like blood cells and proteins. Hemodialysis is typically performed in patients with end-stage renal disease (ESRD) or severe kidney...
93
Peritoneal Dialysis I: Introduction and Procedure01:30

Peritoneal Dialysis I: Introduction and Procedure

Peritoneal dialysis (PD) is a procedure that facilitates the exchange of solutes, waste products, electrolytes, and excess fluid between the blood in the peritoneal capillaries and a dialysis solution introduced into the peritoneal cavity.Principles of Peritoneal Dialysis (PD)Diffusion: Waste products such as urea and electrolytes move from high concentrations in the blood to low concentrations in the dialysate across the peritoneal membrane. This mechanism is driven by the concentration...
85
Renal Drug Clearance: Comparison Between Renal Excretion Methods01:08

Renal Drug Clearance: Comparison Between Renal Excretion Methods

Renal clearance is a critical parameter encompassing kidney filtration, secretion, and reabsorption processes. It is calculated using a specific equation to determine the rate at which the kidneys clear a drug.
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
205