Enhanced absorption of infrared light for quantum wells in coupled pillar-cavity arrays

Optics Express
|March 2, 2023
PubMed

Related Concept Videos

IR Absorption Frequency: Hybridization01:21

IR Absorption Frequency: Hybridization

Hydrocarbons such as alkanes, alkenes, and alkynes show characteristic C–H stretching absorption bands. These IR stretching frequencies depend on the hybridization of the involved carbon atom and can be explained in terms of the s character of each hybridized atomic orbital.
Among the sp, sp2, and sp3 hybridized orbitals, sp orbitals have the maximum s character (50%). Consequently, the electrons are held more closely to the nucleus, resulting in stronger and shorter C–H bonds that...
735
IR Absorption Frequency: Delocalization01:04

IR Absorption Frequency: Delocalization

Electron delocalization refers to the distribution of electrons across multiple atoms within a molecule rather than being confined to a single atom or bond. This phenomenon is common in systems with conjugated bonds—structures where alternating single and double bonds allow π-electrons to move freely across the network. The movement of electrons stabilizes the molecule and can affect various chemical properties, including vibrational frequencies observed in IR spectroscopy.
In IR...
852
Atomic Absorption Spectroscopy: Radiation and Light Sources01:13

Atomic Absorption Spectroscopy: Radiation and Light Sources

Atomic absorption spectroscopy (AAS) relies on the Beer-Lambert law, which requires that the radiation source emits a narrow range of wavelengths to match the absorption characteristics of the analyte atom. The primary criteria for choosing an appropriate radiation source in AAS is to provide a precise and intense emission at specific wavelengths that will allow accurate detection of the analyte.
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
461
Infrared (IR) Spectroscopy: Overview01:09

Infrared (IR) Spectroscopy: Overview

When electromagnetic radiation passes through a material, atoms or molecules transition from a lower to a higher energy state by absorbing radiation corresponding to the energy difference between the two states. The absorption of infrared (IR) radiation causes transitions between vibrational energy levels in a molecule. Therefore, IR spectroscopy is a useful analytical tool for determining the molecular structure of molecules.
Different compounds display unique properties due to their...
2.0K
IR Spectrum Peak Intensity: Amount of IR-Active Bonds00:55

IR Spectrum Peak Intensity: Amount of IR-Active Bonds

When infrared radiation is passed through a molecule, absorption occurs if the molecule's vibration leads to a substantial change in its bond dipole moment. Transitions between vibrational energy levels, typically corresponding to infrared frequencies (4000–400 cm−1), allow absorption if the vibration significantly alters the dipole moment, making the molecule infrared active. The molecular bonds have different stretching and bending vibrations, resulting in various peaks with...
676
Photoluminescence: Applications01:14

Photoluminescence: Applications

Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
461