Driving Pressure, Elastance, and Outcomes in a Real-World Setting: A Bi-Center Analysis of Electronic Health Record
Andrew J Goodwin1, Daniel L Brinton2, Charles Terry1
1Division of Pulmonary, Critical Care, Allergy, and Sleep Medicine, Department of Medicine, Medical University of South Carolina, Charleston, SC.
Abstract:
Emerging evidence suggests the potential importance of inspiratory driving pressure (DP) and respiratory system elastance (ERS) on outcomes among patients with the acute respiratory distress syndrome. Their association with outcomes among heterogeneous populations outside of a controlled clinical trial is underexplored. We used electronic health record (EHR) data to characterize the associations of DP and ERS with clinical outcomes in a real-world heterogenous population.
Design:
Observational cohort study.
Setting:
Fourteen ICUs in two quaternary academic medical centers.
Patients:
Adult patients who received mechanical ventilation for more than 48 hours and less than 30 days.
Interventions:
None.
Measurements And Main Results:
EHR data from 4,233 ventilated patients from 2016 to 2018 were extracted, harmonized, and merged. A minority of the analytic cohort (37%) experienced a Pao2/Fio2 of less than 300. A time-weighted mean exposure was calculated for ventilatory variables including tidal volume (VT), plateau pressures (PPLAT), DP, and ERS. Lung-protective ventilation adherence was high (94% with VT < 8.5 mL/kg, time-weighted mean VT = 6. 8 mL/kg, 88% with PPLAT ≤ 30 cm H2O). Although time-weighted mean DP (12.2 cm H2O) and ERS (1.9 cm H2O/[mL/kg]) were modest, 29% and 39% of the cohort experienced a DP greater than 15 cm H2O or an ERS greater than 2 cm H2O/(mL/kg), respectively. Regression modeling with adjustment for relevant covariates determined that exposure to time-weighted mean DP (> 15 cm H2O) was associated with increased adjusted risk of mortality and reduced adjusted ventilator-free days independent of adherence to lung-protective ventilation. Similarly, exposure to time-weighted mean ERS greater than 2 cm H2O/(mL/kg) was associated with increased adjusted risk of mortality.
Conclusions:
Elevated DP and ERS are associated with increased risk of mortality among ventilated patients independent of severity of illness or oxygenation impairment. EHR data can enable assessment of time-weighted ventilator variables and their association with clinical outcomes in a multicenter real-world setting.
More Related Videos
Related Concept Videos
Methods of Documentation VII: EMR
Errors occurring during blood pressure monitoring
Several factors...
Health Information Technology and Healthcare Information System
Health Information Technology, commonly called HIT, integrates advanced information systems and technology in healthcare settings. Its primary functions include:
Issues And Trends In Healthcare Delivery System
Cost Containment
Payment for healthcare services has historically promoted adoption of costly and often unnecessary or inefficient...
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast,...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.