Commercial Smart Watches and Heart Rate Monitors: A Concurrent Validity Analysis
Samuel Montalvo1, Armando Martinez2, Sabrina Arias2
1Wu Tsai Human Performance Alliance, Division of Cardiovascular Medicine, Stanford School of Medicine, Stanford University, Stanford, California.
Abstract:
Montalvo, S, Martinez, A, Arias, S, Lozano, A, Gonzalez, MP, Dietze-Hermosa, MS, Boyea, BL, and Dorgo, S. Smartwatches and commercial heart rate monitors: a concurrent validity analysis. J Strength Cond Res 37(9): 1802-1808, 2023-The purpose of this study was to explore the concurrent validity of 2 commercial smartwatches (Apple Watch Series 6 and 7) against a clinical criterion device (12-lead electrocardiogram [ECG]) and a field criterion device (Polar H-10) during exercise. Twenty-four male collegiate football players and 20 recreationally active young adults (10 men and 10 women) were recruited and participated in a treadmill-based exercise session. The testing protocol included 3 minutes of standing still (resting), then walking at low intensity, jogging at a moderate intensity, running at a high intensity, and postexercise recovery. The intraclass correlation (ICC 2,k ), and Bland-Altman plot analyses showed a good validity of the Apple Watch Series 6 and Series 7 with increased error (bias) as jogging and running speed increased in the football and recreational athletes. The Apple Watch Series 6 and 7 are highly valid smartwatches at rest and different exercise intensities, with validity decreasing with increased running speed. Strength and conditioning professionals and athletes can confidently use the Apple Watch Series 6 and 7 when tracking heart rate; however, caution must be taken when running at moderate or higher speeds. The Polar H-10 can surrogate a clinical ECG for practical applications.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Holter Monitor: 24-Hour Monitoring
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Special considerations while measuring pulse
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...