Evaluation of Analyte Transfer between Microfluidic Droplets by Mass Spectrometry
Emory M Payne1, Maryam Taraji2,3,4, Bridget E Murray1
1Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48103, United States.
None:
Droplet microfluidics enables high-throughput experimentation and screening by encapsulating chemical and biochemical samples in aqueous droplets segmented by an immiscible fluid. In such experiments, it is critical that each droplet remains chemically distinct. A common approach is to use fluorinated oils with surfactants to stabilize droplets. However, some small molecules have been observed to transport between droplets under these conditions. Attempts to study and mitigate this effect have relied on evaluating crosstalk using fluorescent molecules, which inherently limits the analyte scope and conclusions drawn about the mechanism of the effect. In this work, transport of low molecular weight compounds between droplets was investigated using electrospray ionization mass spectrometry (ESI-MS) for measurement. The use of ESI-MS significantly expands the scope of analytes that can be tested. We tested 36 structurally diverse analytes that were found to exhibit crosstalk ranging from negligible to complete transfer using HFE 7500 as the carrier fluid and 008-fluorosurfactant as a surfactant. Using this data set, we developed a predictive tool showing that high log P and log D values correlate with high crosstalk, and high polar surface area and log S correlate with low crosstalk. We then investigated several carrier fluids, surfactants, and flow conditions. It was discovered that transport is strongly dependent on all of these factors and that experimental design and surfactant tailoring can reduce carryover. We present evidence for mixed crosstalk mechanisms including both micellar and oil partitioning transfer. By understanding the driving mechanisms, surfactant and oil compositions can be designed to better reduce chemical transport for screening workflows.
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Mass Spectrometry: Overview
Mass Analyzers: Overview
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Mass Spectrometers
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...