Related Experiment Video
Updated: Aug 8, 2025

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Sub 4 minute superfast single-photon emission computed tomography/computed tomography as an add-on for
Amanda C Isherwood1, Rita Cabral2, Ged Avery2
1Nuclear Medicine Department, Castle Hill Hospital, Cottingham.
Abstract:
Whole-body bone scintigraphy remains widely used in nuclear medicine as it is a relatively inexpensive and quick test in which the whole body can be imaged with good sensitivity. However, one downside of the technique is its lack of specificity. The difficulty comes when there is a single 'hot spot' which usually requires further anatomical imaging to identify the cause and differentiate malignant from benign lesions. In this situation, hybrid imaging with single-photon emission computed tomography/computed tomography (SPECT/CT) can be a useful problem solver. The addition of SPECT/CT can however, be time-consuming, adding up to 15-20 min for every bed position required, a process that can tax the compliance of the patient and reduce the scanning capacity of the department. We report the successful implementation of a new superfast SPECT/CT protocol comprising a 1 s per view over 24 views point and shoot approach, reducing the SPECT scan time to less than 2 min and the whole SPECT/CT to under 4 min while still producing images that allow diagnostic certainty in previously equivocal lesions. This is faster than previously reported ultrafast SPECT/CT protocols. The utility of the technique is demonstrated in a pictorial review of four disparate causes of solitary bone lesions: fracture, metastasis, degenerative arthropathy and Paget's disease. This technique may prove a cost-effective problem-solving adjunct in nuclear medicine departments unable to yet offer whole-body SPECT/CT to every patient, without adding much burden to the department's gamma camera usage and patient throughput.
More Related Videos
07:10A Sectioning, Coring, and Image Processing Guide for High-Throughput Cortical Bone Sample Procurement and Analysis for Synchrotron Micro-CT
Published on: June 12, 2020
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...