Background:
Manipulation under anesthesia (MUA) is an established option for improving motion in patients presenting with early stiffness following total knee arthroplasty (TKA). Intra-articular corticosteroid injections (IACI) are sometimes administered adjunctively, yet literature examining their efficacy and safety remains limited.
Study Design:
Retrospective, Level IV.
Methods:
A total of 209 patients (TKA = 230) were retrospectively examined to determine the incidence of prosthetic joint infections within 3 months following manipulation with IACI. Approximately 4.9% of initial patients had inadequate follow-up where the presence of infection could not be determined. Range of motion was assessed in patients who had follow-up at or beyond one year (n = 158) and was recorded over multiple time points.
Results:
No infections (0 of 230) were identified within 90 days of receiving IACI during TKA MUA. Before receiving TKA (preindex), patients averaged 111° of total arc of motion and 113° of flexion. Following index procedures, just prior to manipulation (pre-MUA), patients averaged 83° and 86° of total arc and flexion motion, respectively. At final follow-up, patients averaged 110° of total arc of motion and 111° of flexion. At six weeks following manipulation, patients had gained a mean of 25° and 24° of their total arc and flexion motion found at 1 year. This motion was preserved through a 12-month follow-up period.
Conclusion:
Administering IACI during TKA MUA does not harbor an elevated risk for acute prosthetic joint infections. Additionally, its use is associated with substantial increases in short-term range of motion at six weeks following manipulation, which remain preserved through long-term follow-up.