Comparative Evaluation of Fixed Functional Cantilever Space Maintainer and Fixed Nonfunctional Space Maintainer: A
Savitha Sathyaprasad1, Monika Godilli Krishnareddy2, Vinisha Vinod3
1Department of Pedodontics and Preventive Dentistry, KVG Dental College and Hospital, Sullia, Karnataka, India.
The fixed functional cantilever (FFC) space maintainer shows promise as a viable alternative to the fixed nonfunctional (FNF) type, offering better patient acceptance. While FFC had a lower longevity rate, it presented fewer complications than FNF space maintainers.
Area of Science:
- Pediatric Dentistry
- Orthodontics
- Biomaterials
Background:
- Early loss of primary molars necessitates space maintainers to prevent mesial drift.
- Fixed nonfunctional (FNF) space maintainers, like the crown and loop, have drawbacks including poor aesthetics and solder loop fracture.
- A novel fixed functional cantilever (FFC) space maintainer using composite resin aims to overcome FNF limitations.
Purpose of the Study:
- To evaluate and compare the longevity and patient acceptance of the FFC space maintainer against the conventional FNF space maintainer.
- To assess complications and failure criteria for both space maintainer designs over a nine-month period.
Main Methods:
- A randomized controlled trial involved 20 children (aged 6-9) with bilateral premature loss of lower deciduous first molars.
- FFC and FNF space maintainers were placed in contralateral quadrants for each child.
- Patient acceptance was measured using a visual analog scale, and complications were monitored at 3, 6, and 9 months.
Main Results:
- Patient acceptability was significantly higher for the FFC space maintainer compared to the FNF type.
- The FNF space maintainer demonstrated a higher longevity rate (85%) than the FFC space maintainer (70%).
- Common FFC failures included crown/pontic fracture and attrition, while FNF failures involved solder joint fracture and cement loss.
Conclusions:
- The fixed functional cantilever (FFC) space maintainer is a viable alternative to conventional fixed nonfunctional (FNF) space maintainers.
- FFC space maintainers offer improved patient acceptance, though longevity requires further investigation.
- Further research is needed to optimize FFC design for enhanced durability.