Related Experiment Video
Updated: Aug 8, 2025

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
LC-MS/MS method for simultaneous quantification of osilodrostat and metyrapone in human plasma from patients treated
David Balakirouchenane1, Axelle Vasseur2, Fidéline Bonnet-Serrano3
1Department of Pharmacokinetics and Pharmacochemistry, Cochin Hospital, AP-HP, CARPEM, 75014 Paris, France; Université Paris Cité, UMR8038 CNRS, U1268 INSERM, Faculty of Pharmacy, CARPEM, 75006 Paris, France.
Abstract:
Steroidogenesis inhibitors such as metyrapone (MTP) and osilodrostat (ODT) have a key role in the medical treatment of endogenous Cushing's Syndrome (ECS). Both drugs are characterized by a high inter-individual variability of response and require a dose-titration period to achieve optimal control of cortisol excess. However, PK/PD data remain scarce for both molecules and a pharmacokinetically guided approach could help reaching eucortisolism more rapidly. We aimed to develop and validate a liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the simultaneous quantification of ODT and MTP in human plasma. After addition of isotopically labeled internal standard (IS), plasma pretreatment consisted in protein precipitation with acetonitrile including 1% formic acid (v/v). Chromatographic separation was performed on Kinetex® HILIC (4.6 × 50 mm; 2.6 µm) analytical column with an isocratic elution during the 2.0-min run time. The method was linear from 0.5 to 250 ng/mL for ODT and from 2.5 to 1250 ng/mL for MTP. Intra- and inter-assay precisions were < 7.2%, with an accuracy ranging from 95.9% to 114.9%. The IS-normalized matrix effect ranged from 106.0% to 123.0% (ODT) and from 107.0% to 123.0% (MTP) and the range of the IS-normalized extraction recovery was 84.0-101.0% for ODT and 87.0-101.0% for MTP. The LC-MS/MS method was successfully applied in patients' plasma samples (n = 36), trough concentration of ODT and MTP ranged from 2.7 ng/mL to 8.2 ng/mL and from 10.8 ng/mL to 27.8 ng/mL, respectively. Incurred sample reanalysis exhibits less than 14% difference between the first and the second analysis for both drugs. This accurate and precise method, meeting all validation criteria, can therefore be used for plasma drug monitoring of ODT and MTP within the dose-titration period.
More Related Videos
10:13Author Spotlight: An Efficient Methodology to Confidently Differentiate and Characterize Fentanyl Analogs
Published on: November 8, 2024
06:14Optimized LC-MS/MS Method for the High-throughput Analysis of Clinical Samples of Ivacaftor, Its Major Metabolites, and Lumacaftor in Biological Fluids of Cystic Fibrosis Patients
Published on: October 15, 2017