Related Experiment Video
Updated: Aug 8, 2025

Assessing Cerebral Autoregulation via Oscillatory Lower Body Negative Pressure and Projection Pursuit Regression
Published on: December 10, 2014
Photoplethysmography waveform analysis for classification of vascular tone and arterial blood pressure: Study based
N I Echeverría1, A G Scandurra1, C M Acosta2
1Laboratorio de Bioingeniería, ICYTE-CONICET, Facultad de Ingeniería, Universidad Nacional de Mar del Plata, Buenos Aires, Argentina.
Background:
To test whether a Shallow Neural Network (S-NN) can detect and classify vascular tone dependent changes in arterial blood pressure (ABP) by advanced photopletysmographic (PPG) waveform analysis.
Methods:
PPG and invasive ABP signals were recorded in 26 patients undergoing scheduled general surgery. We studied the occurrence of episodes of hypertension (systolic arterial pressure (SAP) >140 mmHg), normotension and hypotension (SAP < 90 mmHg). Vascular tone according to PPG was classified in two ways: 1) By visual inspection of changes in PPG waveform amplitude and dichrotic notch position; where Classes I-II represent vasoconstriction (notch placed >50% of PPG amplitude in small amplitude waves), Class III normal vascular tone (notch placed between 20-50% of PPG amplitude in normal waves) and Classes IV-V-VI vasodilation (notch <20% of PPG amplitude in large waves). 2) By an automated analysis, using S-NN trained and validated system that combines seven PPG derived parameters.
Results:
The visual assessment was precise in detecting hypotension (sensitivity 91%, specificity 86% and accuracy 88%) and hypertension (sensitivity 93%, specificity 88% and accuracy 90%). Normotension presented as a visual Class III (III-III) (median and 1st-3rd quartiles), hypotension as a Class V (IV-VI) and hypertension as a Class II (I-III); all p < .0001. The automated S-NN performed well in classifying ABP conditions. The percentage of data with correct classification by S-ANN was 83% for normotension, 94% for hypotension, and 90% for hypertension.
Conclusions:
Changes in ABP were correctly classified automatically by S-NN analysis of the PPG waveform contour.
Related Concept Videos
Neural Regulation of Blood Pressure
Baroreceptor Reflex
Baroreceptors, located in the carotid sinuses and aortic arch, detect changes in blood pressure. When blood pressure rises, these stretch-sensitive receptors...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Measurement of Blood Pressure
Pulse
The pulse serves as a clinical...
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:

