Development, initial validation, and application of a visual read method for [18F]MK-6240 tau PET
Joanna L Shuping1, Dawn C Matthews2, Katarzyna Adamczuk3
1Enigma Biomedical Group Toronto Ontario Canada.
Alzheimer'S & Dementia (New York, N. Y.)
|March 6, 2023
Summary
A new visual read method for [18F]MK-6240 tau positron emission tomography (PET) scans is highly reproducible and clinically relevant. This method reliably classifies tau PET scans for Alzheimer's disease (AD) identification and staging.
Area of Science:
- Neuroimaging
- Radiopharmaceutical Development
- Alzheimer's Disease Diagnostics
Background:
- The [18F]MK-6240 positron emission tomography (PET) radiotracer targets neurofibrillary tangles (NFTs) in Alzheimer's disease (AD).
- It demonstrates high specificity, sensitivity, and low background signal in the brain.
- Clinical application requires a standardized visual assessment method for identifying and staging AD.
Purpose of the Study:
- To develop and validate a reproducible, clinically relevant visual read method for [18F]MK-6240 PET scans.
- To support the identification and staging of AD subjects compared to non-AD individuals and controls.
Main Methods:
- Five expert readers initially assessed 30 mixed-diagnosis scans, providing input on assessment features and clinical relevance.
- A four-class visual read classification system was defined based on reader input and scan characteristics.
- The method was validated through training two naïve readers, testing inter-rater agreement on 131 scans, and applying it to a diverse database of 1842 scans.
Main Results:
- A four-class visual read method was established: no uptake, medial temporal lobe (MTL) only, MTL and neocortical uptake, or uptake outside MTL.
- Excellent inter-rater reliability was achieved, with kappas of 1.0 for naïve readers and 0.98 for independent readers.
- All 1842 scans in the diverse database were successfully classified, with frequencies aligning with NFT histopathology literature.
Conclusions:
- The developed four-class visual read method for [18F]MK-6240 tau PET is trainable, reproducible, and clinically relevant.
- It accurately captures tau distribution patterns, including medial temporal, neocortical, and atypical patterns, supporting disease staging.
- This method facilitates the clinical use of [18F]MK-6240 PET for Alzheimer's disease assessment.