Related Experiment Video
Updated: Aug 8, 2025

Computerized Adaptive Testing System of Functional Assessment of Stroke
Published on: January 7, 2019
Comparing Patient-Reported Outcomes Measurement Information System Computer Adaptive Testing With Existing Measures
Roos J M Havermans1, Koen W W Lansink2, Taco Gosens3
1Brabant Trauma Registry, Network Emergency Care Brabant, Tilburg, The Netherlands.
Introduction:
Patient-Reported Outcomes Measurement Information System (PROMIS) enables the use of computer adaptive testing (CAT). The aim of this prospective cohort study was to compare the most commonly used disease-specific instruments with PROMIS CAT questionnaires in patients with trauma.
Methods:
All patients with trauma (ages 18-75) who underwent an operative intervention for an extremity fracture between June 1, 2018, and June 30, 2019, were included. The disease-specific instruments were the Quick Disabilities of the Arm, Shoulder, and Hand for upper extremity fractures and the Lower Extremity Functional Scale (LEFS) for lower extremity fractures. Pearson's correlation (r) between the disease-specific instruments and the PROMIS CAT questionnaires (PROMIS Physical Function, PROMIS Pain Interference, and PROMIS Ability to Participate in Social Roles and Activities) was calculated at week 2, week 6, month 3, and month 6. Construct validity and responsiveness were calculated.
Results:
A total of 151 patients with an upper extremity fracture and 109 patients with a lower extremity fracture were included. At month 3 and month 6, the correlation was strong between the LEFS and PROMIS Physical Function (r = 0.88 and r = 0.90, respectively), and at month 3, the correlation was strong between the LEFS and PROMIS Social Roles and Activities (r = 0.72). At week 6, month 3, and month 6, there was a strong correlation between the Quick Disabilities of the Arm, Shoulder, and Hand and PROMIS Physical Function (r = 0.74, r = 0.70, and r = 0.76, respectively).
Conclusions:
The PROMIS CAT measures are acceptably related to existing non-CAT instruments and may be a useful tool during follow-up after operative interventions for extremity fractures.
More Related Videos
09:01Treatment of Ankle Osteoarthritis with Total Ankle Replacement Through a Lateral Transfibular Approach
Published on: January 24, 2018
09:51The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve
Published on: September 7, 2022