Related Experiment Video
Updated: Aug 7, 2025

Author Spotlight: Advancing Endoscopic Ossiculoplasty – Techniques, Innovations, and Practical Guidance for Clinical Integration
Published on: January 26, 2024
Complications Following Alloplastic Chin Augmentation: A Systematic Review of Implant Materials and Surgical
Christopher D Liao, Ezequiel Rodriguez1, Kelley Zhao2
1Department of Anesthesiology, Boston University Medical Center, Boston, MA.
Background:
Alloplastic implantation has become a popular method of chin augmentation. Historically, silicone was the most commonly used implant, but porous materials have grown in favor due to improved fibrovascularization and stability. Nevertheless, it is unclear which implant type has the most favorable complication profile. This systematic review aims to compare the complications of published chin implants and surgical approaches to provide data-driven recommendations for optimizing chin augmentation outcomes.
Methods:
The PubMed® database was queried on March 14, 2021. We selected studies reporting data on alloplastic chin augmentation excluding additional procedures such as osseous genioplasty, fat grafting, autologous grafting, and fillers. The following complications were extracted from each article: malposition, infection, extrusion, revision, removal, paresthesias, and asymmetry.
Results:
Among the 39 articles analyzed, the year of publication ranged from 1982 to 2020; additionally, 31 were retrospective case series, 5 were retrospective cohort or comparative studies, 2 were case reports, and 1 was a prospective case series. More than 3104 patients were included. Among the 11 implants reported, the 3 implants with the highest number of publications were silicone, high-density porous polyethylene (HDPE), and expanded polytetrafluoroethylene (ePTFE). Silicone demonstrated the lowest rates of paresthesias (0.4%) compared to HDPE (20.1%, P < 0.01) and ePTFE (3.2%, P < 0.05). In contrast, there were no statistically significant differences in rates of implant malposition, infection, extrusion, revision, removal, or asymmetry when stratified by implant type. Various surgical approaches were also documented. Compared with subperiosteal implant placement, the dual-plane technique demonstrated higher rates of implant malposition (2.8% vs 0.5%, P < 0.04), revision (4.7% vs 1.0%, P < 0.001), and removal (4.7% vs 1.1%, P < 0.01), but a lower incidence of paresthesias (1.9% vs. 10.8%, P < 0.01). Compared with extraoral incisions, intraoral incisions resulted in higher rates of implant removal (1.5% vs 0.5%, P < 0.05) but lower rates of asymmetry (0.7% vs 7.5%, P < 0.01).
Conclusion:
Silicone, HDPE, and ePTFE had low overall complication rates, demonstrating an acceptable safety profile regardless of implant selection. Surgical approach was found to significantly influence complications. Additional comparative studies on surgical approach while controlling for implant type would be beneficial for optimizing alloplastic chin augmentation practices.
More Related Videos
05:54Real-Time Dynamic Navigation System for the Precise Quad-Zygomatic Implant Placement in a Patient with a Severely Atrophic Maxilla
Published on: October 18, 2021
07:16Author Spotlight: Development of a Novel Finite Element Analysis Model for Improved Orthognathic Surgical Techniques
Published on: October 20, 2023