Related Experiment Video
Updated: Aug 7, 2025

Multi-Modal Home Sleep Monitoring in Older Adults
Published on: January 26, 2019
Night-to-night reliability and agreement of obstructive sleep apnea pathophysiologic mechanisms estimated with
Thomas M Tolbert1, Reagan L Schoenholz1, Ankit Parekh1
1Division of Pulmonary, Critical Care, and Sleep Medicine, Icahn School of Medicine at Mount Sinai, New York, NY, USA.
Study Objectives:
Phenotyping using polysomnography (PUP) is an algorithmic method to quantify physiologic mechanisms underlying obstructive sleep apnea (OSA): loop gain (LG1), arousal threshold (ArTH), and upper airway collapsibility (Vpassive) and muscular compensation (Vcomp). The consecutive-night test-retest reliability and agreement of PUP-derived estimates are unknown. From a cohort of elderly (age ≥55 years), largely non-sleepy, community-dwelling volunteers who underwent in-lab polysomnography (PSG) on 2 consecutive nights, we determined the test-retest reliability and agreement of PUP-estimated physiologic factors.
Methods:
Participants who had an apnea-hypopnea index (AHI3A) of at least 15 events per hour on the first night were included. PUP analyses were performed on each of the two PSGs from each participant. Physiologic factor estimates were derived from NREM sleep and compared across nights using intraclass correlation coefficients for reliability and smallest real differences (SRD) for agreement.
Results:
Two PSGs from each of 43 participants (86 total) were analyzed. A first-night effect was evident with increased sleep time and stability and decreased OSA severity on the second night. LG1, ArTH, and Vpassive demonstrated good reliability (ICC > 0.80). Vcomp had modest reliability (ICC = 0.67). For all physiologic factors, SRD values were approximately 20% or more of the observed ranges, suggesting limited agreement of longitudinal measurements for a given individual.
Conclusions:
For NREM sleep in cognitively normal elderly individuals with OSA, PUP-estimated LG1, ArTH, and Vpassive demonstrated consistent relative ranking of individuals (good reliability) on short-term repeat measurement. For all physiologic factors, longitudinal measurements demonstrated substantial intraindividual variability across nights (limited agreement).
More Related Videos
07:54Drug-Induced Sleep Endoscopy DISE with Target Controlled Infusion TCI and Bispectral Analysis in Obstructive Sleep Apnea
Published on: December 6, 2016
09:38Generalized Psychophysiological Interaction PPI Analysis of Memory Related Connectivity in Individuals at Genetic Risk for Alzheimer's Disease
Published on: November 14, 2017
Related Concept Videos
Sleep Apnea
The condition is more prevalent among...
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History