Related Concept Videos

EDTA: Indirect and Alkalimetric Titration01:23

EDTA: Indirect and Alkalimetric Titration

Unlike direct titration, back-titration, and displacement titration, indirect titration is an EDTA titration method for quantifying anions. In the indirect titration method, anions are precipitated as their insoluble salts with excess metal ions. The filtrate containing the excess metal ions is directly titrated with standard EDTA until the endpoint is achieved. Another approach involves extracting the metal ion and back-titrating with standard EDTA to obtain the endpoint. In this way, the...
1.0K
Effects of EDTA on End-Point Detection Methods01:18

Effects of EDTA on End-Point Detection Methods

Different methods, such as visual observance of metal-ion indicators, spectroscopic techniques, and potentiometric methods, can determine the endpoint of an EDTA titration.
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
320
Titration of Polyprotic Base with a Strong Acid01:18

Titration of Polyprotic Base with a Strong Acid

The titration of a polyprotic base such as sodium carbonate with a strong acid such as hydrochloric acid results in two equivalence points on the titration curve. At the first equivalence point, the carbonate ions in the base are completely converted to bicarbonate ions. The second equivalence point corresponds to the complete conversion of bicarbonate ions to carbonic acid, which dissociates into carbon dioxide and water. The region before the first equivalence point corresponds to the...
841
Complexometric EDTA Titration Curves01:20

Complexometric EDTA Titration Curves

EDTA titration curves determine the free metal ion concentration. The titration curve represents the change in concentration of free metal ions (p function) as a function of the volume of EDTA added. This curve consists of three regions: before, at, and after equivalence points. Excess free metal ions are present before the equivalence point. Equal concentrations of metal ions and EDTA are present at the equivalence point. After the equivalence point, excess EDTA exists. This means slight...
1.0K
Precipitation Titration: Endpoint Detection Methods01:19

Precipitation Titration: Endpoint Detection Methods

In argentometric precipitation titrations, endpoints can be detected visually by the Mohr, Volhard, and Fajans methods. In the Mohr method, adding a soluble chromate indicator gives an initial yellow color to the analyte solution. As the titrant is added, the first excess of silver ions forms a red silver chromate precipitate, marking the endpoint. The solution pH should be maintained at about 8 by adding solid CaCO3.
In the Volhard method, a standard excess of AgNO3 is first added to the...
1.9K
Potentiometric Titration: Overview01:31

Potentiometric Titration: Overview

Potentiometric titration is a quantitative analytical technique that determines the concentration of an analyte by measuring the potential difference between the two electrodes in the solution. The endpoint of a potentiometric titration is the point at which there is a significant change in the potential difference. It occurs when the stoichiometric reaction between the analyte and the titrant is complete. The endpoint is usually determined graphically by plotting the measured potential...
1.7K