Related Experiment Video
Updated: Aug 7, 2025

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Incidence of PSMA PET thyroid incidentaloma depends on analysis method and tracer
Maarten L Donswijk1, Marceline W Piek2, Zing Cheung3
1Department of Nuclear Medicine, Netherlands Cancer Institute-Antoni Van Leeuwenhoek Hospital, Plesmanlaan 121, NL-1066 CX, Amsterdam, The Netherlands. m.donswijk@nki.nl.
Objective:
To investigate the incidences of prostate-specific membrane antigen (PSMA) thyroid incidentaloma (PTI) using different methods to define PTI, to compare the incidence of PTI among different PSMA PET tracers, and to evaluate the clinical consequences of PTI.
Methods:
PSMA PET/CT scans in consecutive patients with primary prostate cancer were analyzed for the presence of PTI using a structured visual (SV) analysis reporting any elevated thyroidal uptake; a semi-quantitative (SQ) analysis using a SUVmax thyroid/bloodpool (t/b) ratio ≥ 2.0 as cutoff; and an analysis of PTI incidence in the clinical reports (RV analysis).
Results:
A total of 502 patients were included. The incidence of PTIs was 22% in the SV analysis, 7% in the SQ analysis, and 2% in the RV analysis. PTI incidences differed significantly from 29 to 64% (SQ, resp. SV analysis) for [18F]PSMA-1007, 7 to 23% for [68Ga]PSMA-11, 2 to 8% for [18F]DCFPyL, and to 0% for [18F]PSMA-JK-7. The majority of PTI in the SV and SQ analyses consisted of diffuse (72-83%) and/or only slightly elevated thyroidal uptake (70%). Inter-observer agreement in the SV analysis was substantial (kappa = 0.76-0.78). During follow-up (median 16.8 months), there were no thyroid-related adverse events except in three patients.
Conclusions:
The incidence of PTI varies greatly among different PSMA PET tracers and is strongly dependent on the analysis method applied. PTI may safely be restricted to focal thyroidal uptake with a SUVmax t/b ratio ≥ 2.0. The clinical pursuit of a PTI must be weighed up to the expected outcome of the underlying disease.
Key Points:
• Thyroid incidentalomas (PTIs) are recognized in PSMA PET/CT. • Incidence of PTI varies greatly among PET tracers and analysis methods. • Incidence of thyroid-related adverse events in PTI cases is low.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET

