Related Experiment Video
Updated: Aug 7, 2025

Treatment of Ankle Osteoarthritis with Total Ankle Replacement Through a Lateral Transfibular Approach
Published on: January 24, 2018
Axial and Sagittal Rotation of Cementless Tibial Baseplates Occurs in Bone Under Joint Loading
Matthew G Teeter1, Jordan S Broberg2, James L Howard3
1Department of Medical Biophysics, Schulich School of Medicine & Dentistry, Western University, London, ON, Canada; Department of Surgery, Schulich School of Medicine & Dentistry, Western University, London, ON, Canada; Imaging Group, Robarts Research Institute, Schulich School of Medicine & Dentistry, Western University, London, ON, Canada.
Background:
There has been a recent increase in the use of cementless fixation for primary total knee arthroplasty. While the early results of contemporary cementless implants are promising, understanding the behavior of cementless tibial baseplates under loading remains an ongoing interest. The objective of this study was to identify the pattern of displacement that occurred under loading for a single cementless tibial baseplate design at one year post operation for stable and continuously migrating implants.
Methods:
There were 28 subjects from a previous trial of a pegged highly porous cementless tibial baseplate evaluated. Subjects underwent supine radiostereometric exams from two weeks through one year after surgery. At one year, subjects also underwent a standing radiostereometric exam. Fictive points on the tibial baseplate model were used to relate translations to anatomical locations. Migration over time was calculated to determine if subjects displayed stable or continuous migration. The magnitude of inducible displacement between the supine and standing exams was calculated.
Results:
Inducible displacement patterns were similar between stable and continuously migrating tibial baseplates. Displacements were greatest in the anterior-posterior axis followed by the lateral-medial axis. Correlation of displacements between adjacent fictive points in these axes indicated an axial rotation of the baseplate occurred under loading (r2 = 0.689-0.977, P < .001). Less displacement occurred in the superior-inferior axis and correlations indicated an anterior-posterior tilt of the baseplate occurred under loading (r2 = 0.178-0.226, P = .009-.023).
Discussion:
From supine to standing position the predominant pattern of displacement for this cementless tibial baseplate was axial rotation, with some subjects also displaying an anterior-posterior tilt.
Related Concept Videos
Eccentric Axial Loading in a Plane of Symmetry
General Case of Eccentric Axial Loading
Consider a member subjected to equal and opposite forces that are applied along a line that does not coincide with the member's neutral axis. In unsymmetrical...
Normal Strain under Axial Loading
Knee Joint
A total of seven ligaments support the knee joint. The patellar ligament, which is also attached to the quadriceps femoris...
Bones of the Lower Limb: Tibia and Fibula
Ankle Joint

