ECG-guided non-invasive estimation of pulmonary congestion in patients with heart failure
Aniruddh Raghu1,2,3, Daphne Schlesinger1,2,3,4, Eugene Pomerantsev5,6
1Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Building 36-796, 77 Massachusetts Ave., Cambridge, MA, 02139, USA.
Abstract:
Quantifying hemodynamic severity in patients with heart failure (HF) is an integral part of clinical care. A key indicator of hemodynamic severity is the mean Pulmonary Capillary Wedge Pressure (mPCWP), which is ideally measured invasively. Accurate non-invasive estimates of the mPCWP in patients with heart failure would help identify individuals at the greatest risk of a HF exacerbation. We developed a deep learning model, HFNet, that uses the 12-lead electrocardiogram (ECG) together with age and sex to identify when the mPCWP > 18 mmHg in patients who have a prior diagnosis of HF. The model was developed using retrospective data from the Massachusetts General Hospital and evaluated on both an internal test set and an independent external validation set, from another institution. We developed an uncertainty score that identifies when model performance is likely to be poor, thereby helping clinicians gauge when to trust a given model prediction. HFNet AUROC for the task of estimating mPCWP > 18 mmHg was 0.8 [Formula: see text] 0.01 and 0.[Formula: see text] 0.01 on the internal and external datasets, respectively. The AUROC on predictions with the highest uncertainty are 0.50 [Formula: see text] 0.02 (internal) and 0.[Formula: see text] 0.04 (external), while the AUROC on predictions with the lowest uncertainty were 0.86 ± 0.01 (internal) and 0.82 ± 0.01 (external). Using estimates of the prevalence of mPCWP > 18 mmHg in patients with reduced ventricular function, and a decision threshold corresponding to an 80% sensitivity, the calculated positive predictive value (PPV) is 0.[Formula: see text] 0.01when the corresponding chest x-ray (CXR) is consistent with interstitial edema HF. When the CXR is not consistent with interstitial edema, the estimated PPV is 0.[Formula: see text] 0.02, again at an 80% sensitivity threshold. HFNet can accurately predict elevated mPCWP in patients with HF using the 12-lead ECG and age/sex. The method also identifies cohorts in which the model is more/less likely to produce accurate outputs.
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Heart Failure IV: Classification and Diagnostic Evaluation
Heart Failure V: Medical Management
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Cardiac Catheterization II: Right Heart Catheterization
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...