Correlation between patient-specific quality assurance in volumetric modulated arc therapy and 2D dose image features
Yixiao Guo1, Jinyan Hu2, Yang Li3
1Department of Radiation Oncology, Gansu Provincial Hospital, Lanzhou, 730000, People's Republic of China.
Abstract:
In radiotherapy, air-filled ion chamber detectors are ubiquitously used in routine dose measurements for treatment planning. However, its use has been restricted by intrinsic low spatial resolution barriers. We developed one procedure for patient-specific quality assurance (QA) in arc radiotherapy by coalescing two adjacent measurement images into a single image to improve spatial resolution and sampling frequency, and investigated how different spatial resolutions affect the QA results. PTW 729 and 1500 ion chamber detectors were used for dosimetric verification via coalescing two measurements with 5 mm-couch shift and the isocenter, and only isocenter measurement, which we call coalescence and standard acquisition (SA). Statistical process control (SPC), process capability analysis (PCA), and receiver operating characteristic (ROC) curve were used to compare the performance of the two procedures in determining tolerance levels and identifying clinically relevant errors. By analyzing 1256 γ values calculated on interpolated data points, our results indicated that detector 1500 showed higher averages in coalescence cohorts at different tolerance criteria and the dispersion degrees were spread out smaller. Detector 729 yielded a slightly lower process capability of 0.79, 0.76, 1.10, and 1.34, but detector 1500 exhibited somewhat different results of 0.94, 1.42, 1.19, and 1.60 in magnitude. The results of SPC individual control chart showed that cases in coalescence cohorts with γ values lowering its lower control limit (LCL) were greater than those in SA cohorts for detector 1500. A combination of the width of multi-leaf collimator (MLC) leaf, the cross-sectional area of the single detector, and the spacing between adjacent detectors might lead to discrepancies in percent γ values across diverse spatial resolution scenarios. The accuracy of reconstructed volume dose is mainly determined by the interpolation algorithm used in dosimetric systems. The magnitude of filling factor in the ion chamber detectors determined its ability to detect dose deviations. SPC and PCA results indicated that coalescence procedure could detect more potential failure QA results than SA while enhancing action thresholds.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies III: Computed Tomography