Aims:
The purpose of this study was to evaluate the efficacy of steam heat for inactivation of SARS-CoV-2 when applied to materials common in mass transit installations.
Methods And Results:
SARS CoV-2 (USA-WA1/2020) was resuspended in either cell culture media or synthetic saliva, inoculated (∼1 × 106 TCID50) onto porous and nonporous materials and subjected to steam inactivation efficacy tests as either wet or dried droplets. The inoculated test materials were exposed to steam heat ranging from 70°C to 90°C. The amount of infectious SARS-CoV-2 remaining after various exposure durations ranging from 1 to 60 s was assessed. Higher steam heat application resulted in higher inactivation rates at short contact times. Steam applied at 1-inch distance (∼90°C at the surface) resulted in complete inactivation for dry inoculum within 2 s of exposure (excluding two outliers of 19 test samples at the 5-s duration) and within 2-30 s of exposure for wet droplets. Increasing the distance to 2 inches (∼70°C) also increased the exposure time required to achieve complete inactivation to 15 or 30 s for materials inoculated with saliva or cell culture media, respectively.
Conclusions:
Steam heat can provide high levels of decontamination (>3 log reduction) for transit-related materials contaminated with SARS-CoV-2 using a commercially available steam generator with a manageable exposure time of 2-5 s.
Related Concept Videos
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Physical Methods for Controlling Microbial Growth: Temperature
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Physical Methods for Controlling Microbial Growth: Radiation and Filtration