Related Experiment Video
Updated: Aug 7, 2025

Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
The Role of CT-Guided Optimal Fluoroscopic Viewing Angle for Coronary Engagement After TAVR
Horacio A Medina de Chazal1, Ali Zgheib1, Abdullah Al Isma'ili1
1Division of Cardiology, Department of Medicine, McGill University Health Center, Glen Hospital, Montreal, Quebec, Canada.
Abstract:
We report the case of an 89-year-old woman with prior transcatheter aortic valve replacement who underwent successful left coronary artery engagement and left circumflex percutaneous coronary intervention using patient-specific computed tomography fluoroscopic projections. (Level of Difficulty: Advanced.).
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Cardiac Catheterization III: Left Heart Catheterization