The Rigid Tube as an Alternative in Controlling the Problematic Airway
Published on: June 6, 2020
Tracheostomy insertion in COVID-19: insertion practice and factors leading to unplanned tube exchange
Peter McCauley1, Amr Mohammed1, Michelle Casey2
1Department of Anaesthesia and Critical Care Medicine, Beaumont Hospital, Dublin, Ireland.
Background:
Tracheostomy insertion in patients with coronavirus disease 2019 (COVID-19) presents unique challenges. Patients frequently have high ventilatory requirements, and as an aerosol generating procedure, tracheostomy insertion creates the potential for staff transmission. Problems with tracheostomies contribute to morbidity and mortality, and tracheostomy changes may increase risks of staff transmission. We sought to quantify the incidence of clinically necessitated tracheostomy changes, establish the indications for change and investigate the incidence of staff transmission.
Methods:
We conducted a single institution, retrospective, observational cohort study of all intensive care unit (ICU) patients with COVID-19 who had a tracheostomy between March 2020 and April 2021. The institution is a large tertiary referral centre in Ireland.
Results:
Forty-three patients had a tracheostomy during the study period. All were a Shiley™ Flexible Adult Taperguard or Shiley™ XLT Tracheostomy. 14 patients (33%) required a tracheostomy change, with the majority (57%) involving a change from a standard size to an extended length tracheostomy. Persistent leak was the most common indication for change (71.6%). Other indications included patient-ventilator dyssynchrony, persistent cough and accidental decannulation. No staff transmission of COVID-19 occurred during this study.
Conclusions:
The incidence of tracheostomy change was 33%, highlighting the importance of selecting the right tracheostomy for each patient. We discuss how key characteristics of tracheostomies such as type, size, length and inner diameter may impact flow, resistance and work of breathing, leading to unplanned tracheostomy change. No staff transmission occurred arising from tracheostomy insertion, adding to increasing evidence that tracheostomy insertion in COVID-19 appears safe with adherence to guidelines describing the correct use of personal protective equipment.
Related Concept Videos
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask...
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes:
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....