Related Experiment Video
Updated: Aug 7, 2025

Morphological and Functional Assessment of the Right Ventricle Using 3D Echocardiography
Published on: October 28, 2020
Right ventricular electromechanical dyssynchrony in adults with repaired Tetralogy of Fallot
Daniel Bowen1, Martijn Kauling1, Bernardo Loff Barreto1
1Department of Cardiology, Erasmus Medical Center, Rotterdam, Netherlands.
Background And Purpose:
Electromechanical dyssynchrony, manifested by right bundle branch block and regional wall mechanical dysfunction, contributes to inefficient RV function in repaired Tetralogy of Fallot (ToF). This study aims to evaluate the synchronicity of multiple RV walls using two-dimensional multi-plane echocardiography (2D-MPE) in order to augment current understanding of the mechanisms behind RV dyssynchrony.
Methods:
Sixty-nine adult ToF patients [aged 33 (23-45) years; 61% male] and twenty-five matched healthy controls underwent deformational analysis of the RV lateral, anterior, inferior and septal walls following 2D-MPE acquisitions. RV synchronicity was assessed by the intra-RV deformation delay between each basal RV wall and mid-septal segment in addition to mechanical dispersion calculated across four, six and eight segments (MD).
Results:
All RV wall-septum delays plus MD-4 and MD-6 indices were significantly greater in ToF patients compared to healthy controls (p < 0.001-0.03). In ToF patients, the lateral and anterior RV walls were last to reach peak deformation and anterior wall longitudinal strain was lower (p = 0.001). Post systolic shortening of at least one RV wall segment was identified in 19 (28%) ToF patients. Despite similar ECG characteristics, lateral and anterior wall-septum delays were significantly longer in patients with greater degrees of dyssynchrony (73 [37-108]ms vs. 37 [0-63]ms, p = 0.006; 91 [52-116]ms vs. 41 [1-69]ms, p = 0.013), although RV ejection fraction (RVEF) was not significantly lower. MD-4 and MD-8 indices displayed moderate negative associations with RVEF, strengthened by inclusion of lateral wall longitudinal strain (r = 0.64/0.65; p ≤0.01).
Conclusion:
RV dyssynchrony in ToF is characterised by electromechanical delays between the lateral, anterior and septal walls, with anterior wall dysfunction likely associated with surgical repair of the RV outflow tract. Prospectively, 2D-MPE may have an emerging role evaluating RV mechanical response to electrical resynchronisation therapy.
More Related Videos
06:04Author Spotlight: Establishment and Confirmation of a Postnatal Right Ventricular Volume Overload Mouse Model
Published on: June 9, 2023
08:19Transthoracic Echocardiography to Assess Post-Resuscitation Left Ventricular Dysfunction After Acute Myocardial Infarction and Cardiac Arrest in Pigs
Published on: July 12, 2022
Related Concept Videos
Cardiomyopathy II: Dilated Cardiomyopathy
Mitral Regurgitation I: Introduction
Mitral Stenosis I: Introduction
Dysrhythmias IV: Characteristics of Bradyarrhythmias
Mitral Stenosis II: Clinical features and Diagnostic Tests