Related Experiment Video
Updated: Aug 7, 2025

Cone Beam Intraoperative Computed Tomography-based Image Guidance for Minimally Invasive Transforaminal Interbody Fusion
Published on: August 6, 2019
Equivalent radiation exposure with robotic total hip replacement using a novel, fluoroscopic-guided (CT-free) system:
Graham Buchan1, Christian Ong1, Christian Hecht1
1Department of Orthopaedic Surgery, Cleveland Clinic Foundation, Cleveland, OH, USA.
Abstract:
Accurate and precise positioning of the acetabular cup remains a prevalent challenge in total hip arthroplasty (THA). Robotic assistance for THA has increased over the past decade due to the potential to improve the accuracy of implant placement. However, a common criticism of existing robotic systems is the requirement for preoperative computerized tomography (CT) scans. This additional imaging increases patient radiation exposure, as well as cost, and requires pin placement during surgery. The goal of this study was to analyze the radiation burden associated with a novel, CT-free robotic THA system compared to an unassisted manual THA approach (n = 100/arm). On average, the study cohort had a higher number of fluoroscopic images captured (7.5 vs. 4.3 images; p < 0.001), radiation dose (3.0 vs. 1.0 mGy; p < 0.001), and a longer duration of radiation exposure (18.8 vs. 6.3 s; p < 0.001), per procedure, than the control group. Additionally, no learning curve was detected by CUSUM analysis with respect to the number of fluoroscopic images taken during the adoption of the robotic THA system. While statistically significant, in comparison to published literature, the radiation exposure of the CT-free robotic THA system was comparable to that of unassisted manual THA approach and less than that of CT-based robotic approaches. Thus, the novel CT-free robotic system likely poses no clinically significant increase in radiation exposure to the patient compared to manual approaches.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...