Related Experiment Video
Updated: Aug 7, 2025

Author Spotlight: Ex Vivo OCT-Based Multimodal Imaging of Human Donor Eyes for Research into Age-Related Macular Degeneration
Published on: May 26, 2023
Predictability of the vault after implantable collamer lens implantation using OCT and artificial intelligence in
Andrea Russo1, Ottavia Filini, Giacomo Savini
1From the Centro Oculistico Bresciano, Brescia, Italy (Russo, Filini, Festa); Eye Clinic, Department of Neurological and Vision Sciences, University of Brescia, Italy (Russo, Morescalchi, Boldini, Semeraro); I.R.C.C.S.-G.B. Bietti Foundation, Rome, Italy (Savini).
Purpose:
To compare the predicted vault using machine learning with the achieved vault using the online manufacturer's nomogram in patients undergoing posterior chamber implantation with an implantable collamer lens (ICL).
Setting:
Centro Oculistico Bresciano, Brescia, Italy, and I.R.C.C.S.-Bietti Foundation, Rome, Italy.
Design:
Retrospective multicenter comparison study.
Methods:
561 eyes from 300 consecutive patients who underwent ICL placement surgery were included in this study. All preoperative and postoperative measurements were obtained by anterior segment optical coherence tomography (AS-OCT; MS-39). The actual vault was quantitatively measured and compared with the predicted vault using machine learning of AS-OCT metrics.
Results:
A strong correlation between model predictions and achieved vaulting was detected by random forest regression (RF; R2 = 0.36), extra tree regression (ET; R2 = 0.50), and extreme gradient boosting regression ( R2 = 0.39). Conversely, a high residual difference was observed between achieved vaulting values and those predicted by the multilinear regression ( R2 = 0.33) and ridge regression ( R2 = 0.33). ET and RF regressions showed significantly lower mean absolute errors and higher percentages of eyes within ±250 μm of the intended ICL vault compared with the conventional nomogram (94%, 90%, and 72%, respectively; P < .001). ET classifiers achieved an accuracy (percentage of vault in the range of 250 to 750 μm) of up to 98%.
Conclusions:
Machine learning of preoperative AS-OCT metrics achieved excellent predictability of ICL vault and size, which was significantly higher than the accuracy of the online manufacturer's nomogram, providing the surgeon with a valuable aid for predicting the ICL vault.
More Related Videos
Related Concept Videos
Angle Closure Glaucoma: Treatment
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Glaucoma: Overview