Localization of cyclopropyl groups and alkenes within glycerophospholipids using gas-phase ion/ion chemistry

De'Shovon M Shenault1, Scott A McLuckey1, Elissia T Franklin1

  • 1Department of Chemistry, Purdue University, West Lafayette, Indiana, USA.

Related Concept Videos

Mass Spectrometry: Cycloalkane Fragmentation01:05

Mass Spectrometry: Cycloalkane Fragmentation

In mass spectrometry, cycloalkanes exhibit distinct fragmentation patterns due to the inherent stability of their molecular ions compared to linear or branched alkanes. The ring structure of cycloalkanes provides additional stability to the molecular ions, often resulting in prominent ion peaks in the mass spectrum.
For example, cyclohexane molecular ions have a mass-to-charge ratio (m/z) of 84, which tends to produce a stronger signal than linear alkanes like hexane. This stability comes from...
1.5K
Gas Chromatography: Introduction01:13

Gas Chromatography: Introduction

Gas chromatography (GC) is a technique for separating and analyzing volatile compounds in a sample. Its primary purpose is to identify and quantify components in complex mixtures, making it essential in fields such as environmental analysis, pharmaceuticals, and petrochemicals. GC is also called vapor-phase chromatography (VPC) or gas-liquid partition chromatography (GLPC).
In GC,  a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
2.1K
Mass Spectrometry: Cycloalkene Fragmentation00:54

Mass Spectrometry: Cycloalkene Fragmentation

The molecular ions of cycloalkenes undergo fragmentation via a retro-Diels–Alder reaction.
1.1K
Gas Chromatography: Types of Columns and Stationary Phases01:17

Gas Chromatography: Types of Columns and Stationary Phases

Gas chromatography (GC) relies on stationary phases to separate and analyze components in a sample. There are two main types of stationary phases: liquid and solid. Liquid stationary phases are non-volatile, thermally stable, and chemically inert liquids coated onto the column. Solid stationary phases are particles of adsorbent material, such as silica gel or molecular sieves.
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
801
Chemical Ionization (CI) Mass Spectrometry01:21

Chemical Ionization (CI) Mass Spectrometry

The molecular ion peak of a molecule in the mass spectrum provides vital information for molecular identification. However, conventional electron impact ionization can lead to the rapid dissociation of some molecular ions before they reach the detector. A milder ionization method is required to increase the lifetime of such ionized analyte molecules. Chemical ionization (CI) is a gas-phase protonation reaction useful for mass-analyzing analyte molecules that are easily protonated to yield the...
814
Gas Chromatography–Mass Spectrometry (GC–MS)01:14

Gas Chromatography–Mass Spectrometry (GC–MS)

Gas chromatography–mass spectrometry (GC–MS) is the combination of analytical techniques of gas chromatography and mass spectrometry in a single instrument for analyzing a mixture of compounds. The gas chromatograph separates the compounds in the mixture, and the mass spectrometer analyzes each compound separately to determine the molecular masses and molecular structures.
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
4.4K