Related Experiment Video
Updated: Aug 7, 2025

Vascularized Composite Hand Allograft Procurement and Preparation for Distal and Proximal Forearm Allotransplantation: A Stepwise Approach
Published on: May 23, 2025
Volar versus dorsal approach for supinator to posterior interosseous nerve transfer: An anatomical study in cadavers
Adil Shahzad Ahmed1, Robert Roundy2, Alexander R Graf2
1Department of Orthopaedic Surgery, Hand & Upper Extremity Surgery, Baylor College of Medicine, Houston, Texas, USA.
Introduction:
Supinator to posterior interosseous nerve (SPIN) transfer allows reconstruction of finger/thumb extension and thumb abduction for low radial nerve palsy, incomplete C6 tetraplegia, and brachial plexus injury affecting C7-T1. No study has compared dorsal versus volar approach to perform SPIN transfer. This comparison is studied in the present work, assessing supinator motor branch length and ability to achieve nerve transfer from either approach.
Methods:
Ten fresh frozen cadavers were randomly allocated to receive either a dorsal or volar approach to PIN and supinator radial and ulnar branches (RB = radial, UB = ulnar). Supinator head innervation patterns were documented. RB and UB lengths, forearm lengths measured from ulnar styloid to olecranon, visualization of extensor carpi radialis brevis (ECRB) motor nerve without additional dissection, and ability to perform tension-free nerve transfer were assessed.
Results:
Nine of 10 specimens had supinator branches innervating both heads. The ECRB nerve was visualized in all volar but only one dorsal approach. No significant differences in forearm length were found. Volar with elbow extended: mean RB length was 35 ± 7.8 mm and UB was 37.8 ± 9.3 mm. Dorsal with elbow extended: mean RB length was 30 ± 4.1 mm and UB was 38.8 ± 7.3 mm. Dorsal with elbow flexed 90°: RB was 25.6 ± 3.8 mm and UB was 34.8 ± 4.8 mm. No significant differences were found in branch lengths between approaches (dorsal vs. volar UB, p = .339; dorsal vs. volar RB, p = .117). All limbs achieved tension-free coaptation.
Conclusion:
Neither approach demonstrated superiority in achieving tension-free nerve transfer. Volar permitted immediate identification of ECRB nerve whereas this was only visualized in one dorsal specimen without additional dissection. Overall, the volar approach allows direct coaptation in elbow extension, mimicking maximal physiologic tension for neurorrhaphy. It simultaneously permits additional procedures for pinch reconstruction via single exposure, circumventing limb/microscope maneuvering, dorsal dissection, and increased operative time. Ultimate choice of approach should depend on surgeon familiarity and potential need for additional simultaneous transfers.
Related Concept Videos
Bones of the Upper Limb: Ulna
Muscles that Move the Forearm
Forearm Flexors
The biceps brachii, brachialis, and brachioradialis are forearm flexors. The biceps brachii is made up of two heads. Its long head originates at the supraglenoid tubercle of the scapula, whereas that of the short head is...
Bones of the Upper Limb: Humerus

