Related Experiment Video
Updated: Aug 7, 2025

A Novel Non-invasive Method for the Detection of Elevated Intra-compartmental Pressures of the Leg
Published on: May 31, 2019
[Design and application of a central venous pressure measurement tool]
1Department of Medical Equipment, Guidong People's Hospital of Guangxi Zhuang Autonomous Region, Wuzhou 543001, Guangxi Zhuang Autonomous Region, China. Corresponding author: Zhong Liming,
Abstract:
Central venous pressure (CVP) reflects the comprehensive condition of effective blood volume, cardiac function and vascular tone. Clinical monitoring of CVP can indirectly understand and evaluate the dynamic changes of blood volume in patients, and provide a reference for patients to venous fluid. At present, the traditional manual measurement method is widely used for measurement, which has some shortcomings such as zero shift, cumbersome operation (requires two health care workers to cooperate). In order to overcome the above problems, the author invented a new fixable CVP measurement tool and obtained the national utility model patent (ZL 2021 2 1451705.7). The tool is mainly composed of a base plate, a movable frame and a measuring department, etc. When used, the base plate is placed into the back of the patient and pressed and fixed, the movable frame is adjusted, the zero point is found, and the measurement data is read from the measuring department. It has the advantages of simple and convenient operation, small measurement error, wide applicability (different body types) and so on, which is suitable for clinical promotion.
More Related Videos
09:57A Protocol to Set Up Needle-Free Connector with Positive Displacement on Central Venous Catheter in Intensive Care Unit
Published on: July 13, 2019
06:27Wireless Telemetry Device Implantation in a Fontan Ovine Model for Continuous and Long-Term Hemodynamic Monitoring
Published on: May 2, 2025
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Parentral Nutrition: Centeral and Peripheral Parental Nutrition
PN can be administered through two primary routes:
1. Central Parenteral Nutrition (CPN):
CPN involves delivering a high concentration of nutrients through a large vein. This is typically achieved using a Peripherally Inserted Central Catheter (PICC) or,...
Pre-Procedural Guidelines for Assessing Blood Pressure