An optimal internal model proportional integral controller to improve pressure tracking profile of artificial
Debasis Acharya1, Dushmanta Kumar Das2
1National Institute of Technology Nagaland, Chumukedima, India.
Abstract:
Mechanical ventilator (MV) is a breathing support medical equipment used during medical surgery or in an intensive care unit (ICU) for critical patients to reduce the breathing work of the patient under ventilation. In this work, a piston-driven mechanical ventilator is studied. Such types of ventilators are generally used as anaesthesia ventilators with volume-controlled modes. A modern ventilator can operate in different modes, such as volume control, pressure control, or both. Pressure-controlled mode may be better suited for some cases, such as patients undergoing laparoscopic surgery, as compared to volume-controlled mode because it may increase compliance during pneumoperitoneum, enhance oxygenation, and lower the stress response postoperatively. The pressure profile of a PCV must exactly track the pressure profile of a patient under ventilation to avoid ventilator-induced diaphragmatic dysfunction. Therefore, an optimal internal model control base proportional integral (IMC-PI) controller is proposed. The optimum parameter of the filter component of the IMC-PI controller is found by an enhanced class topper optimization (ECTO) algorithm. The performance of the proposed controller is analyzed in different scenarios and compared with existing results. Graphical Abstract Optimal internal model proportional integral controller for human respiratory ventilator.
Related Concept Videos
PI Controller: Design
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Time and frequency -Domain Interpretation of PI Control
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...