Age- and sex-stratified normal values for circulatory and ventilatory power during ramp exercise derived from a
Kohei Ashikaga1, Haruki Itoh2,3, Tomoko Maeda2,3
1Department of Sports Medicine, St. Marianna University School of Medicine, 2-16-1 Sugao, Miyamae-ku, Kawasaki, Kanagawa, 216-8511, Japan. k2ashikaga@marianna-u.ac.jp.
Abstract:
Circulatory power (CP) and ventilatory power (VP), obtained by cardiopulmonary exercise testing (CPX), have been suggested to be excellent prognostic markers for heart failure. However, the normal values of these parameters in healthy Japanese populations remain unknown; thus, we aimed to investigate these values in such a population. A total of 391 healthy Japanese participants, 20-78 years of age, underwent CPX with a cycle ergometer with ramp protocols. Systolic blood pressure (SBP), heart rate, oxygen uptake ([Formula: see text]O2) at peak exercise, and the slope of minute ventilation ([Formula: see text]E) versus carbon dioxide ([Formula: see text]CO2) ([Formula: see text]E vs. [Formula: see text]CO2 slope) were measured. CP was calculated by multiplying the peak [Formula: see text]O2 and SBP values, and VP was calculated by dividing the peak SBP value by the [Formula: see text]E versus [Formula: see text]CO2 slope. For males and females, the average CP values were 6119 ± 1280 (mean ± standard deviation) and 4775 ± 914 mmHg·mL/min/kg, respectively (p < 0.001). The average VP values for males and females were 8.0 ± 1.3 and 6.9 ± 1.3 mmHg (p < 0.001). CP decreased with age in both sexes. VP increased with age in females, with no significant change in males. We calculated the normal values for CP and VP in a healthy Japanese population. The results can contribute to the evaluation of patients' CPX results as a reference.
More Related Videos
08:44Author Spotlight: Integrating Alveolar-Capillary Reserve Measurements in Exercise Adaptation and Therapeutic Strategies
Published on: February 2, 2024
07:26Conducting Maximal and Submaximal Endurance Exercise Testing to Measure Physiological and Biological Responses to Acute Exercise in Humans
Published on: October 17, 2018
Related Concept Videos
Respiratory Volumes and Capacities
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...
Lung Capacity
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...