Cleaning efficacy of EDDY versus ultrasonically-activated irrigation in root canals: a systematic review and
Xiaojun Chu1, Shuting Feng1, Weiqing Zhou1
1Department of Endodontics, Stomatological Hospital, School of Stomatology, Southern Medical University, No 366 Jiangnan Avenue South, Guangzhou, 510280, Guangdong, China.
Background:
Ultrasonically-activated irrigation (UAI) is effective in root canal irrigation but may damage canal walls. EDDY is a sonic activation system with flexible working tips that cause no harm to dentinal walls. This review explores the intracanal cleaning efficacy of EDDY compared with UAI in vitro.
Methods:
The systematic review was registered in the PROSPERO database (CRD42021235826). A literature search was conducted in six electronic databases. In vitro studies that compared the removal of smear layer, debris, soft tissue or microbes in root canals between EDDY and UAI were included. Data extraction and quality assessment were performed. Meta-analyses were conducted on smear layer removal and debris elimination with the standardized mean difference (SMD). Heterogeneity was measured using the I2 test and the Chi2 test. The random-effect model was used when I2 > 50%, or p < 0.1, otherwise the fixed-effect model was applied. The level of significance was set at p < 0.05.
Results:
19 articles were included in this systematic review and 7 articles were included in meta-analyses. Meta-analyses on smear layer removal showed unimportant differences between EDDY and UAI at any canal third (coronal [SMD = 0.08, 95% confidence interval (95%CI): -0.29 to 0.45; p = 0.44, I2 = 0%]; middle [SMD = 0.02, 95% CI: -0.44 to 0.47; p = 0.94, I2 = 0%]; apical [SMD = 0.01, 95%CI: -0.35 to 0.38; p = 0.70, I2 = 0%]). Meta-analyses on debris removal evaluated by scanning electron microscope (coronal [SMD = 0.03, 95% CI: -0.41 to 0.46; p = 0.27, I2 = 23%]; middle [SMD = -0.24, 95% CI: -0.83 to 0.35; p = 0.80, I2 = 0%]; apical [SMD = 0.24, 95%CI: -0.20 to 0.67; p = 0.36, I2 = 2%]) and micro-CT (SMD = 0.36, 95% CI: -0.67 to 1.40; p = 0.03, I2 = 70%) both found insignificant differences. No meta-analysis was undertaken on soft-tissue removal and disinfection due to the various study designs, but the qualitative analyses implied that EDDY achieved similar performance to UAI in both aspects.
Conclusions:
Limited evidence indicated that EDDY was comparable to UAI in removing smear layer, debris, soft tissue and microbes ex vivo. Considering UAI may damage canal walls, EDDY might be a substitute for UAI in irrigation activation. But more randomized clinical trials are required to explore the clinical extrapolation of the results in this review.
More Related Videos
11:47Evaluation of the Efficacy of Organic Peroxyacids for Eradicating Dairy Biofilms Using an Approach Combining Static and Dynamic Methods
Published on: December 9, 2022
05:31Imaging and Quantification of the Area of Fast-Moving Microbubbles Using a High-Speed Camera and Image Analysis
Published on: September 5, 2020
Related Concept Videos
Antimicrobial Effectiveness
Hand hygiene
Hand washing...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...