Related Experiment Video
Updated: Aug 6, 2025

Rat Model of Right-Sided Cardiac Remodeling and Arrhythmia Using Pulmonary Artery Banding
Published on: August 30, 2024
Improvements in Accuracy and Confidence in Rhythm Identification After Cardiac Surgery Using the AtriAmp Signals
Diane H Brown1, Xiao Zhang2, Awni M Al-Subu1
1Division of Pediatric Critical Care Medicine, Department of Pediatrics, University of Wisconsin School of Medicine and Public Health, Madison, WI, USA.
Abstract:
Objectives: Following cardiac surgery, 50% to 60% of patients with congenital heart disease will experience an arrhythmia. These arrhythmias are associated with increased morbidity and mortality. Therefore, rapid and accurate identification is paramount to the improvement of patient outcome. We hypothesize that the AtriAmp, a device which allows atrial electrogram (AEG) display on the bedside monitors, will increase provider accuracy and confidence in arrhythmia diagnosis. Design: A prospective observational study. Electrograms were collected from post-operative patients from the bedside monitors surface ECG and an AEG using the AtriAmp. A 12-question online survey was given to critical care and cardiology providers at 9 different programs across the country as well as being posted to the AAP SOCC fall newsletter. Six questions displayed signals from only the surface leads, while the other 6 showed the same arrhythmias with an AEG obtained from the AtriAmp. Answers were then evaluated for confidence and accuracy. A paired t-test along with mixed method modeling was used to assess the data. Setting: Cardiac pediatric ICU. Subjects: Providers in pediatric cardiology and pediatric critical care were evaluated on their ability to diagnose arrhythmias on surface ECG and AEG obtained from bedside monitor. Interventions: The accuracy and confidence of diagnosis of both surface and AEG signals were evaluated through an on-line survey. Results: Eighty-eight providers completed the survey. The study showed that interpreting with the AtriAmp signal, compared to the surface ECG only, significantly increased the accuracy (P = .002) and confidence in provider rhythm diagnosis (P < .001). Junctional ectopic tachycardia, sinus tachycardia, and complete heart block had the most significant increase in accuracy of diagnose when using the AtriAmp signal (P < .001, P = .002, P = .010, respectively). Conclusion: Use of the AtriAmp increased provider accuracy and confidence in post-operative rhythm diagnosis when compared to diagnosis using the surface electrograms only.
More Related Videos
08:10Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
16:40A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Dysrhythmias V: Evaluating Dysrhythmias
Cardiopulmonary Resuscitation III: AED Use
Dysrhythmias VI: Management of Dysrhythmias