Simultaneous Analysis and Efficient Separation of Anabolic Androgenic Steroids in Dietary Supplement by a Validated
Zeinab Saadabadi1, Bahram Daraei1, Farzad Kobarfard2
1Department of Pharmacology and Toxicology, School of Pharmacy, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
Background:
Using sports supplements is common among athletes. The presence of anabolic steroids in sports supplements as a hormonal contaminant can increase production efficiency. Since anabolic steroids cause health problems and result in positive doping tests in athletes, it is important to investigate their presence in the supplement preparations consumed by athletes.
Objectives:
This paper aims to simultaneously determine ten anabolic steroids by high-performance thin-layer chromatography (HPTLC) method in sports supplements.
Methods:
Chromatographic analysis was conducted on glass silica gel 60F254 plates. The extracts loaded on silica gel plates are subjected to programed multiple development (PMD) to separate anabolic androgenic steroids (AASs). Densitometric scanning is carried out at the wavelength of 245 and 366nm. The method was validated according to the ICH guidelines.
Results:
Spots at retardation factor (Rf) 0.72 (elution system 1), 0.4 (elution system 1), 0.29 (elution system 2), 0.25 (elution system 2), 0.1 (elution system 1), 0.65 (elution system 2), 0.59 (elution system 1), 0.44 (elution system 1), 0.8 (elution system 3), and 0.82 (elution system 3) values were recognized as 19-nor androstenedione, 19-nortestosterone, methyl testosterone, clostebol, stanozolol, trenbolone enanthate, oxymetholone, oxandrolone, testosterone enanthate, and nandrolone decanoate, respectively. The linear ranges were 25 - 250 μg/mL for oxymetholone, 7 - 50 μg/mL for 19-nor androstenedione, 19-nortestosterone, and oxandrolone, and 3 - 20 μg/mL for methyl testosterone, clostebol, stanozolol, trenbolone enanthate, testosterone enanthate, and nandrolone decanoate. The developed method is validated by acceptable precision (CV < 20%) and good accuracy (94% < R < 114%). The value of limit of detection (LOD) for all derivatives was in the range of 0.02 - 0.16 μg/spot (20-160 μg/g of supplement), while limit of quantitation (LOQ) was found to be in the range of 0.06 - 0.5 μg/spot (60 - 500 μg/g of supplement). Fifty sports supplement samples as real sample were collected and analyzed. None of the samples screened positive using the HPTLC method.
Conclusions:
In the present study, the fast, cheap, and simple HPTLC method could be used for the multi-residue analysis of ten anabolic androgenic steroids in sports supplements.
More Related Videos
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
11:14Rapid High-throughput Species Identification of Botanical Material Using Direct Analysis in Real Time High Resolution Mass Spectrometry
Published on: October 2, 2016
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
