Multimethod analysis of three rotary instruments produced by electric discharge machining technology
Emmanuel J N L Silva1,2,3, Natasha C Ajuz1, Jorge N R Martins4,5,6
1Department of Endodontics, Grande Rio University (UNIGRANRIO), Rio de Janeiro, Brazil.
Aim:
This study aimed to compare three rotary instruments produced by the EDM process with the heat-treated ProTaper Gold system regarding design, metallurgy, mechanical properties and shaping ability.
Methodology:
HyFlex EDM (25/~), Neoniti (25/.06), EDMax (25/.06) and ProTaper Gold (25/.08v) instruments (n = 58 per group) were compared regarding design, metallurgy and mechanical performance. Unprepared canal areas were calculated for each system after preparation of mesiobuccal, mesiolingual and distal canals of mandibular molars (15 canals per group) using micro-CT technology. Statistical analyses were performed using One-way anova post-hoc Tukey and Kruskal-Wallis post-hoc Dunn's tests (α = 5%).
Results:
All instruments had asymmetrical blades, no radial lands, no major defects and almost equiatomic nickel/titanium ratios, but different cross-section designs, tip geometries and surface appearances. Although instruments had distinct transformation temperature curves, they showed crystallographic martensitic arrangement at 21°C and mixed austenite plus R-phase at body temperature. Neoniti and HyFlex EDM showed similar results in all mechanical tests (p > .05), while EDMax and ProTaper Gold had similar time to fracture (p = .841), maximum bending load (p = .729), and cutting ability (p = .985). ProTaper Gold showed the highest torque to failure (p < .001) and HyFlex EDM had the lowest buckling resistance (p < .001). Mean percentages of unprepared canal areas ranged from 20.4% to 25.7% in the mesial canals, and from 20.8% to 26.2% in the distal canal, with no statistical differences among systems (p > .05).
Conclusions:
Instruments' geometry and phase transformation temperatures influenced the results of the mechanical tests, but not their shaping ability.
More Related Videos
07:37Full-field Strain Measurements for Microstructurally Small Fatigue Crack Propagation Using Digital Image Correlation Method
Published on: January 16, 2019
03:07Scanning Electron Microscopic Evaluation of Surface Defects of Remover Retreatment File After Single and Multiple Uses
Published on: October 11, 2024
Related Concept Videos
Response Surface Methodology
The process of RSM involves several key steps:
Mechanical Efficiency of Real Machines
However, in reality, no machine can be truly ideal, and all of them experience some...