Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
Transcatheter Aortic Valve Replacement in Large Annuli Valves With the Supra-Annular, Self-Expandable Evolut Platform
Luis Augusto P Dallan1, Gilbert Tang2, John K Forrest3
1Harrington Heart and Vascular Institute, University Hospitals Cleveland Medical Center, OH (L.A.P.D., C.B., G.F.A.).
Background:
Transcatheter aortic valve replacement is approved for treatment of patients with severe aortic stenosis across the spectrum of risk. While considering broader indications for use, transcatheter aortic valve replacement in large native annuli has become increasingly important.
Methods:
Patients with tricuspid aortic stenosis undergoing transcatheter aortic valve replacement using the Evolut R or Evolut PRO+ 34 mm valves (Medtronic, Minneapolis, MN) in the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry between October 2016 and September 2020 were stratified according to in range (>12%) device oversizing and below range (0%-12%) device oversizing. Patients undergoing valve-in-valve procedures, having a baseline annulus size <26 or ≥34 mm, or without computed tomography angiography measured annulus size were excluded. Percentage of oversizing was calculated as [(valve diameter-annulus diameter)×100/annulus diameter].
Results:
Transcatheter aortic valve replacement in patients with large annuli was performed in 8017 patients with a mean (±SD) age 79.3±7.9 years and 94% were male. Below range (n=1096) was less common than in range oversizing (n=6921). At 1-year follow-up, mortality (19.6% versus 14.9%; P=0.001), aortic valve reintervention (2.1% versus 0.6%; P<0.001) and valve-related readmission rates (3.2% versus 2.0%; P=0.014) were higher in the below range device oversizing group versus in range group respectively. In a multivariable Cox proportional hazards regression model, when controlling for clinically relevant covariates, below range device oversizing was associated with higher 1-year all-cause mortality (HR, 1.28 [CI, 1.07-1.51]; P=0.005).
Conclusions:
Results from the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry in patients with large annuli valves using 34mm Evolut R/PRO+ valves suggest that in range (>12%) device oversizing delivered better clinical outcomes than implantation with below range (0%-12%) device oversizing.
More Related Videos
09:57Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
07:46Author Spotlight: Revolutionizing Remote Surgery with Augmented Reality and Robotics for Enhanced Precision and Accessibility
Published on: August 9, 2024
Related Concept Videos
Aortic Regurgitation III: Medical Management
Aortic Regurgitation I: Introduction
Mitral Valve Prolapse II: Assessment and Management
Thoracic Aorta
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...