Related Experiment Video
Updated: Aug 6, 2025

Preparation, Purification, and Characterization of Lanthanide Complexes for Use as Contrast Agents for Magnetic Resonance Imaging
Published on: July 21, 2011
Contrast Agent Selection to Prevent Recurrent Severe Hypersensitivity Reaction to Iodinated Contrast Media Based on
Jhii-Hyun Ahn1, Seung-Phil Hong2, Tae-Hwa Go3
1From the Departments of Radiology.
Objective:
To investigate the incidence of severe iodinated contrast media (ICM)-related hypersensitivity reaction (HSR) and to find the optimal alternative ICM to reduce the risk of severe HSR recurrence.
Methods:
We retrospectively reviewed 23,383,183 cases of ICM administration between January 2015 and December 2019 from the nationwide health insurance database. We classified ICMs based on generic profiles and the presence of N-(2,3-dihydroxypropyl) carbamoyl side chains. The incidence of severe and recurrent severe HSRs was calculated, and χ2 tests were performed to compare the prevalence of severe HSR according to ICM groups. In addition, logistic regression analyses were used to assess differences between ICM groups.
Results:
The incidence of severe HSRs was 1.92% (450,067 of 23,282,183). Among 1,875,245 individuals who received ICM twice on different days, severe HSR occurred in 40,850 individuals, and severe HSR recurred in 3319 individuals (8.12%). The risk of recurrence significantly decreased when the ICM changed (9.24% vs 7.08%, P < 0.001), especially when the ICM changed to one with a different side chain (6.74%, P < 0.001). In addition, compared with the reuse of the culprit agent, using combinations of iobitridol/iohexol (odds ratio [OR], 0.696; P = 0.04), iohexol/iopamidol (OR, 0.757; P = 0.007), iopamidol/iohexol (OR, 0.447; P < 0.001), and ioversol/iohexol (OR, 0.683; P = 0.04) reduced the risk of recurrence of severe HSR.
Conclusions:
Changing the culprit ICM to that with a different side chain can reduce severe HSR recurrence. The optimal choice of an alternative ICM depends on the causative agent.
More Related Videos
11:27Preparation and In Vitro Characterization of Dendrimer-based Contrast Agents for Magnetic Resonance Imaging
Published on: December 4, 2016
09:08Enhancing Efficiency and Radiolabeling Yields of Carbon-11 Radioligands for Clinical Research Using the Loop Method
Published on: December 20, 2024
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Cardiac Catheterization IV: Nursing Management
Imaging Studies VII: Vascular Imaging