Related Experiment Video
Updated: Aug 6, 2025

A Magnetic Resonance Imaging Protocol for Stroke Onset Time Estimation in Permanent Cerebral Ischemia
Published on: September 16, 2017
Quantifying infarct core volume in ischemic stroke: What is the optimal threshold and parameters of computed
Chuluunbaatar Otgonbaatar1, Ji Ye Lee2, Keun-Hwa Jung3
1Department of Radiology, College of Medicine, Seoul National University, Seoul, Republic of Korea.
Objective:
Although computed tomography perfusion (CTP) is used to select and guide decision-making processes in patients with acute ischemic stroke, there is no clear standardization of the optimal threshold to predict ischemic core volume accurately. The infarct core volume with a relative cerebral blood flow(rCBF) threshold of < 30% is commonly used. We aimed to assess the volumetric agreement of the infarct core volume with different CTP parameters and thresholds using CTP software (RAPID, VITREA) and the infarct volume on diffusion-weighted imaging (DWI), with a short interval time (within 60 min) between CTP and follow-up DWI.
Materials And Methods:
This retrospective study included 42 acute ischemic stroke patients with occlusion of the large artery in the anterior circulation between April 2017-November 2020. RAPID identified infarct core as tissue rCBF < 20-38%. VITREA defined the infarct core as cerebral blood volume (CBV) < 26-56%. Olea Sphere was used to measure infarct core volume on DWI. The CTP-infarct core volume with different thresholds of perfusion parameters (CBF threshold vs CBV threshold) were compared with DWI-infarct core volumes.
Results:
The median time between CTP and DWI was 37.5min. The commonly used threshold of CBV< 41% (4.3 mL) resulted in lower median infarct core volume difference compared to the commonly used thresholds of rCBF < 30% (8.2mL). On the other hand, the optimal thresholds of CBV < 26% (-1.0mL; 95% CI, -53.9 to 58.1 mL; 0.945) resulted in the lowest median infarct core volume difference, narrowest limits of agreement, and largest interclass correlation coefficient compared with the optimal thresholds of rCBF < 38% (4.9 mL; 95% CI, -36.4 to 62.9 mL; 0.939).
Conclusion:
Our study found that the both optimal and commonly used thresholds of CBV provided a more accurate prediction of the infarct core volume in patients with AIS than rCBF.
More Related Videos
10:25Brain Infarct Segmentation and Registration on MRI or CT for Lesion-symptom Mapping
Published on: September 25, 2019
09:48Quantification of Neurovascular Protection Following Repetitive Hypoxic Preconditioning and Transient Middle Cerebral Artery Occlusion in Mice
Published on: May 4, 2015
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Imaging Studies III: Computed Tomography
Imaging Studies VII: Vascular Imaging
Imaging Studies for Cardiovascular System IV: CMRI