Related Experiment Video
Updated: Aug 5, 2025

Experimental Approach to Examine Leptin Signaling in the Carotid Bodies and its Effects on Control of Breathing
Published on: October 25, 2019
CORP: Sources and degrees of variability in whole animal intermittent hypoxia experiments
Zishan Zhang1,2, Hardik Kalra3, Matthew C Delzell3,4
1Interdisciplinary Graduate Program in Molecular Medicine, University of Iowa, Iowa City, Iowa, United States.
Abstract:
Chamber exposures are commonly used to evaluate the physiological and pathophysiological consequences of intermittent hypoxia in animal models. Researchers in this field use both commercial and custom-built chambers in their experiments. The purpose of this Cores of Reproducibility in Physiology paper is to demonstrate potential sources of variability in these systems that researchers should consider. Evaluating the relationship between arterial oxygen saturation and inspired oxygen concentration, we found that there are important sex-dependent differences in the commonly used C57BL6/J mouse model. The time delay of the oxygen sensor that provides feedback to the system during the ramp-down and ramp-up phases was different, limiting the number of cycles per hour that can be conducted and the overall stability of the oxygen concentration. The time to reach the hypoxic and normoxic hold stages, and the overall oxygen concentration, were impacted by the cycle number. These variables were further impacted by whether there are animals present in the chamber, highlighting the importance of verifying the cycling frequency with animals in the chamber. At ≤14 cycles/h, instability in the chamber oxygen concentration did not impact arterial oxygen saturation but may be important at higher cycle numbers. Taken together, these data demonstrate the important sources of variability that justify reporting and verifying the target oxygen concentration, cycling frequency, and arterial oxygen concentration, particularly when comparing different animal models and chamber configurations.NEW & NOTEWORTHY Intermittent hypoxia exposures are commonly used in physiology and many investigators use chamber systems to perform these studies. Because of the variety of chamber systems and protocols used, it is important to understand the sources of variability in intermittent hypoxia experiments that can impact reproducibility. We demonstrate sources of variability that come from the animal model, the intermittent hypoxia protocol, and the chamber system that can impact reproducibility.
More Related Videos
05:45Delivery of In Vivo Acute Intermittent Hypoxia in Neonatal Rodents to Prime Subventricular Zone-derived Neural Progenitor Cell Cultures
Published on: November 2, 2015
08:51Multiple Intravenous Bolus Dosing and Invasive Hemodynamic Assessment in a Hypoxia-Induced Mouse Pulmonary Artery Hypertension Model
Published on: November 11, 2022