Related Experiment Video
Updated: Aug 5, 2025

Diagnosing Pulmonary Tuberculosis with the Xpert MTB/RIF Test
Published on: April 9, 2012
Accuracy of computer-aided chest X-ray in community-based tuberculosis screening: Lessons from the 2016 Kenya
Brenda Mungai1,2,3, Jane Ong'angò4, Chu Chang Ku5
1Department of Clinical Sciences, Liverpool School of Tropical Medicine, Liverpool, United Kingdom.
Abstract:
Community-based screening for tuberculosis (TB) could improve detection but is resource intensive. We set out to evaluate the accuracy of computer-aided TB screening using digital chest X-ray (CXR) to determine if this approach met target product profiles (TPP) for community-based screening. CXR images from participants in the 2016 Kenya National TB Prevalence Survey were evaluated using CAD4TBv6 (Delft Imaging), giving a probabilistic score for pulmonary TB ranging from 0 (low probability) to 99 (high probability). We constructed a Bayesian latent class model to estimate the accuracy of CAD4TBv6 screening compared to bacteriologically-confirmed TB across CAD4TBv6 threshold cut-offs, incorporating data on Clinical Officer CXR interpretation, participant demographics (age, sex, TB symptoms, previous TB history), and sputum results. We compared model-estimated sensitivity and specificity of CAD4TBv6 to optimum and minimum TPPs. Of 63,050 prevalence survey participants, 61,848 (98%) had analysable CXR images, and 8,966 (14.5%) underwent sputum bacteriological testing; 298 had bacteriologically-confirmed pulmonary TB. Median CAD4TBv6 scores for participants with bacteriologically-confirmed TB were significantly higher (72, IQR: 58-82.75) compared to participants with bacteriologically-negative sputum results (49, IQR: 44-57, p<0.0001). CAD4TBv6 met the optimum TPP; with the threshold set to achieve a mean sensitivity of 95% (optimum TPP), specificity was 83.3%, (95% credible interval [CrI]: 83.0%-83.7%, CAD4TBv6 threshold: 55). There was considerable variation in accuracy by participant characteristics, with older individuals and those with previous TB having lowest specificity. CAD4TBv6 met the optimal TPP for TB community screening. To optimise screening accuracy and efficiency of confirmatory sputum testing, we recommend that an adaptive approach to threshold setting is adopted based on participant characteristics.
More Related Videos
Related Concept Videos
Pulmonary Tuberculosis IV
Several diagnostic approaches are used to detect TB. The conventional method is the Tuberculin Skin Test (TST), also known as the Mantoux test. However, this method has...
Pulmonary Tuberculosis I
Causative Organism
The primary infectious agent causing tuberculosis is Mycobacterium tuberculosis, a slow-growing, acid-fast, aerobic rod that exhibits sensitivity to heat and ultraviolet light. Instances of Mycobacterium bovis and Mycobacterium avium contributing to the development of TB infection are rare.
Mode of...
Pulmonary Tuberculosis V
Latent tuberculosis infection occurs when TB bacteria are present in a person's body, but are not causing illness or symptoms. It is not contagious, and preventive treatment is crucial to avoid the...
Pulmonary Tuberculosis II
Here is a detailed explanation of its pathophysiology:
Transmission: The process begins when a person inhales droplet nuclei containing M. tuberculosis. These are typically released into the air when an individual with pulmonary or...
Pulmonary Tuberculosis III
The first classification is based on the development of the disease, and it includes the following categories:
Radiological Investigation I: X-ray and CT

