Preliminary investigation into the prediction of indicators of beef spoilage using Raman and Fourier transform
Qingsen Liu1, Pengcheng Dong1, Lemonia-Christina Fengou2
1Lab of Beef Processing and Quality Control, College of Food Science and Engineering, Shandong Agricultural University, Tai'an, Shandong 271018, PR China.
Abstract:
The objective of this study was to assess the potential to predict the microbial beef spoilage indicators by Raman and Fourier transform infrared (FT-IR) spectroscopies. Vacuum skin packaged (VSP) beef steaks were stored at 0 °C, 4 °C, 8 °C and under a dynamic temperature condition (0 °C ∼ 4 °C ∼ 8 °C, for 36 d). Total viable count (TVC) and total volatile basic nitrogen (TVB-N) were obtained during the storage period along with spectroscopic data. The Raman and FTIR spectra were baseline corrected, pre-processed using Savitzky-Golay smoothing and normalized. Subsequently partial least squares regression (PLSR) models of TVC and TVB-N were developed and evaluated. The root mean squared error (RMSE) ranged from 0.81 to1.59 (log CFU/g or mg/100 g) and the determination coefficient (R2) from 0.54 to 0.75. The performance of PLSR model based on data fusion (combination of Raman and FT-IR data) is better than that based on Raman spectra and similar to that of FT-IR. Overall, Raman spectroscopy, FT-IR spectroscopy, and a combination of both exhibited a potential for the prediction of the beef spoilage.
More Related Videos
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Applications of IR Spectroscopy: Overview
IR Frequency Region: Fingerprint Region
IR and UV–Vis Spectroscopy of Carboxylic Acids
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency,...
Infrared (IR) Spectroscopy: Overview
Different compounds display unique properties due to their...