Stacked machine learning models to classify atrial disorders based on clinical ECG features: a method to predict
Dhananjay Budaraju1, Bala Chakravarthy Neelapu1, Kunal Pal1
1Department of Biotechnology and Medical Engineering, National Institute of Technology Rourkela, Odisha, India.
Objectives:
Atrial Tachycardia (AT) and Left Atrial Enlargement (LAE) are atrial diseases that are significant precursors to Atrial Fibrillation (AF). There are ML models for ECG classification; clinical features-based classification is required. The suggested work aims to create stacked ML models that categorize Sinus Rhythm (SR), Sinus Tachycardia (ST), AT, and LAE signals based on clinical parameters for AF prognosis.
Methods:
The classification was based on thirteen clinical parameters, such as amplitude, time domain ECG aspects, and P-Wave Indices (PWI), such as the ratio of P-wave length and amplitude ((P (ms)/P (µV)), P-wave area (µV*ms), and P-wave terminal force (PTFV1(µV*ms). Apart from classifying the ECG signals, the stacked ML models prioritized the clinical features using a pie formula-based technique.
Results:
The Stack 1 model achieves 99% accuracy, sensitivity, precision, and F1 score, while the Stack 2 model achieves 91%, 91%, 94%, and 92% for identifying SR, ST, LAE, and AT, respectively. Both stack models obtained a computational time of 0.06 seconds. PTFV1 (µV*ms), P (ms)/P (µV)), and P-wave area (µV*ms) were ranked as crucial clinical features.
Conclusion:
Clinical feature-based stacking ML models may help doctors obtain insight into important clinical ECG aspects for early AF prediction.
Related Concept Videos
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Dysrhythmias V: Evaluating Dysrhythmias
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Dysrhythmias II: Classification of Tachyarrhythmias